: Multiparametric-Magnetic Resonance Imaging(mp-MRI) presents the ability to detect clinically significant cancer, aiming to avoid biopsy if the results are negative or target an abnormal lesion if a suspected lesion of the prostate is found. Recent guidelines recommend the performance of 12 standard biopsies along with 3 to 5 targeted biopsies in suspected prostate lesions, depending on the size of the prostate lesion. In addition, prostate biopsy can be performed by either the transperineal or the transrectal approach. The aim of this comprehensive review is to highlight the role of both standard and targeted MRI/Ultrasound (US) fusion transperineal biopsy (TPB) in the diagnostic approach of prostate cancer cases, to report its diagnostic efficacy and complication rates and to suggest the promising usage of MRI/US fusion TPB in the future. A comprehensive review of the existing literature, including systematic reviews, meta-analyses, and clinical guidelines, was conducted to compare the efficacy and safety of transperineal and transrectal approaches in prostate cancer detection. Special emphasis was placed on mp-MRI-guided targeted biopsy and its combination with systematic sampling. Prostate biopsy via the transperineal approach is related to increased detection rates, especially for anterior lesions, and decreased infection risk compared to the transrectal approach, while complication rates (hematuria, hemospermia, etc.) remain similar. Due to lower infection rates via the transperineal route, the performance of prostate biopsy using the transperineal approach is strongly recommended. Finally, transperineal fusion MRI/US biopsy can be valuable for repeat biopsies in patients who had an initial negative biopsy or for the follow-up of patients that undergo active surveillance. MRI/US fusion-guided TPB represents a significant advancement in prostate cancer diagnostics, combining improved precision with reduced infection risks. Although TPB presents higher detection rates for anterior prostatic lesions and lower post-biopsy infection rates, there is no significant difference in cancer detection rates compared to TRB. Targeted training and investment may reduce long-term expenses of TPB by lowering hospitalizations, antibiotic usage, and related costs. Future research should further refine this approach and explore its integration with emerging technologies like artificial intelligence for enhanced lesion targeting and diagnostic accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.3390/jcm14020453DOI Listing

Publication Analysis

Top Keywords

prostate cancer
16
prostate biopsy
12
detection rates
12
prostate
10
biopsy
9
transperineal
8
transperineal biopsy
8
transperineal transrectal
8
transrectal approach
8
comprehensive review
8

Similar Publications

Introduction: Prostate cancer (PCa) is the commonest urologic cancer worldwide and the leading cause of male cancer deaths in Nigeria. In Nigeria, orchidectomy remains the primary androgen deprivation therapy. Dihydrotestosterone (DHT) is the active prostatic androgen, but its relationship with PCa severity has not been extensively studied in Africa.

View Article and Find Full Text PDF

We intended to investigate the potential of several transitional zone (TZ) volume-related variables for the detection of clinically significant prostate cancer (csPCa) among lesions scored as Prostate Imaging Reporting and Data System (PI-RADS) category 3. Between September 2018 and August 2023, patients who underwent mpMRI examination and scored as PI-RADS 3 were queried from our institution. The diagnostic performances of prostate-specific antigen density (PSAD), TZ-adjusted PSAD (TZPSAD), and TZ-ratio (TZ volume/whole gland prostate volume) were analyzed.

View Article and Find Full Text PDF

Introduction: In NCCN favorable intermediate-risk (FIR) prostate cancer (PCa) patients treated with radical prostatectomy (RP), we tested the effect of upstaging and upgrading on cancer-specific mortality (CSM).

Methods: Within the SEER database (2010-2021), upstaging (≥pT3a or pN1) and upgrading (ISUP ≥3) rates in FIR RP patients were tabulated. Kaplan-Meier (KM) plots and multivariable Cox-regression models (CRMs) were fitted.

View Article and Find Full Text PDF

Dosimetric comparison of CyberKnife and conventional linac prostate SBRT plans: analysis of the PACE-B Study.

Int J Radiat Oncol Biol Phys

January 2025

The Royal Marsden NHS Foundation Trust, London SM2 5PT, UK; Radiotherapy and Imaging Division, Institute of Cancer Research, London SM2 5NG, UK.

Purpose: In the PACE-B study, a non-randomised comparison of toxicity outcomes between stereotactic body radiotherapy (SBRT) platforms revealed fewer urinary side-effects with CyberKnife (CK) compared to conventional linac (CL) SBRT. This analysis compares baseline characteristics and planning dosimetry between the CK-SBRT and CL-SBRT cohorts in PACE-B, aiming to provide insight into possible reasons for differing toxicity outcomes between the platforms.

Methods: Dosimetric parameters for the surrogate urethra (SU), contoured urethra, bladder, bladder trigone (BT), and rectum were extracted from available CT planning scans of PACE-B SBRT patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!