: Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses preoperative three-dimensional imaging to create cutting blocks tailored to patient anatomy. However, there is debate regarding the additional benefits of PSI in terms of improved alignment or functional outcomes compared to using conventional instruments. Although PSI design has undergone continuous development, the improvements have not been incorporated. Therefore, the aim of this study was to compare the surgical time and radiological outcomes between advanced-design PSI and conventional instruments. : We conducted a retrospective review of 328 patients who underwent primary TKAs using PSI for osteoarthritis and compared them with 328 matched patients who underwent TKA performed with conventional instruments during the same period (March 2023 to August 2024). We compared the surgical time and component alignment between the advanced-design PSI group and the conventional instrument group. : The average surgical time was significantly shorter in the advanced-design PSI group (47.6 ± 12.4 min) compared to the conventional instrument group (59.2 ± 14.2 min, < 0.05). The advanced PSI design group had a significantly lower occurrence of outliers in hip-knee-ankle alignment (7%) compared to the conventional instrument group (36.3%). This trend was also observed in femoral coronal alignment, tibial coronal alignment, and femoral sagittal alignment. : The use of advanced-design PSI demonstrated significantly reduced surgical time and improved alignment compared to conventional instruments. This highlights that proper design is a key factor for PSI to achieve superior biomechanical effects. Our study shows that advanced-design PSI technology has the potential to replace conventional instruments in TKA, though further research is required to determine its clinical outcomes and economic benefits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/jcm14020307 | DOI Listing |
Clin Oral Investig
January 2025
Department of Restorative Dentistry, Dental Materials, and Endodontics, Bauru School of Dentistry, University of São Paulo, Rua Siqueira Campos, 180, Centro, Vitória da Conquista, Bauru, São Paulo, BA, ZIP: 45.000-455, Brazil.
Objective: This study investigated the associations among endodontic instruments, ultrasonic tips and various final irrigation protocols for removing intracanal and intratubular biofilms in long oval canals.
Methodology: One hundred mandibular premolars inoculated with Enterococcus faecalis were divided into two groups: the control group (CG: n = 10), which received no treatment; and the test groups (n = 30), which included saline (SS), sodium hypochlorite (2.5% NaOCl) and chlorhexidine (2% CHX).
Sensors (Basel)
January 2025
Shunde Innovation School, University of Science and Technology Beijing, Foshan 528399, China.
Mid-infrared spectral analysis has long been recognized as the most accurate noninvasive blood glucose measurement method, yet no practical compact mid-infrared blood glucose sensor has ever passed the accuracy benchmark set by the USA Food and Drug Administration (FDA): to substitute for the finger-pricking glucometers in the market, a new sensor must first show that 95% of their glucose measurements have errors below 15% of these glucometers. Although recent innovative exploitations of the well-established Fourier-transform infrared (FTIR) spectroscopy have reached such FDA accuracy benchmarks, an FTIR spectrometer is too bulky. The advancements of quantum cascade lasers (QCLs) can lead to FTIR spectrometers of reduced size, but compact QCL-based noninvasive blood glucose sensors are not yet available.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel, 1050 Brussels, Belgium.
Fluorescence imaging has been widely used in fields like (pre)clinical imaging and other domains. With advancements in imaging technology and new fluorescent labels, fluorescence lifetime imaging is gradually gaining recognition. Our research department is developing the CAM, based on the Current-Assisted Photonic Sampler, to achieve real-time fluorescence lifetime imaging in the NIR (700-900 nm) region.
View Article and Find Full Text PDFSensors (Basel)
January 2025
2Ai, School of Technology, IPCA, 4750-810 Barcelos, Portugal.
Virtual reality (VR) has gained significant attention in various fields including healthcare and industrial applications. Within healthcare, an interesting application of VR can be found in the field of physiotherapy. The conventional methodology for rehabilitating upper limb lesions is often perceived as tedious and uncomfortable.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Civil Engineering Department, Polytechnic School, University of Sao Paulo, São Paulo 05508-220, Brazil.
Using fiber optics as a tool for different kinds of geotechnical monitoring can be highly attractive and cost-effective when compared to conventional instruments, such as piezometers and inclinometers, among others. A single fiber optic cable may cover a larger monitoring area compared to conventional instrumentation and allows for monitoring more than one physical quantity with the same fiber optic cable. The literature provides several different examples of distributed fiber optic systems usage.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!