As medical imaging continues to expand, concerns about the potential risks of ionizing radiation to the developing fetus have led to a preference for non-radiation-based alternatives such as ultrasonography and fetal MRI. This review examines the current evidence on the safety of MRI during pregnancy, with a focus on 3 T MRI and contrast agents, aiming to provide a comprehensive synthesis that informs clinical decision-making, ensures fetal safety and supports the safe use of all available modalities that could impact management. We conducted a comprehensive review of studies from 2000 to 2024 on MRI safety during pregnancy, focusing on 3 T MRI and gadolinium use. The review included peer-reviewed articles and large database studies, summarizing key findings and identifying areas for further research. Fetal MRI, used alongside ultrasound, enhances diagnostic accuracy for fetal anomalies, particularly in the brain, thorax, gastrointestinal and genitourinary systems, with no conclusive evidence of adverse effects on fetal development. While theoretical risks such as tissue heating and acoustic damage exist, studies show no significant harm at 1.5 T or 3 T, though caution is still advised in the first trimester. Regarding gadolinium-based contrast agents, the evidence is conflicting: while some studies suggest risks such as stillbirth and rheumatological conditions, animal studies show minimal fetal retention and no significant toxicity, and later clinical research has not substantiated these risks. The existing literature on fetal MRI is encouraging, suggesting minimal risks; however, further investigation through larger, prospective and long-term follow-up studies is essential to comprehensively determine its safety and late effects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/diagnostics15020208 | DOI Listing |
Eur J Obstet Gynecol Reprod Biol
January 2025
Obstetrics and Fetal Medicine Unit, CHRU of Nancy, Nancy, France; Department of Fetopathology and Placental Pathology, CHRU of Nancy, Nancy, France; Inserm, Diagnostic and Interventional Adaptive Imaging, University of Lorraine, Nancy, France. Electronic address:
Objective: This study aimed to evaluate the utility of fetal MRI in prenatal diagnosis.
Methods: A retrospective study was conducted, including all pregnant women who underwent fetal MRI at a single French university center from 2018 to 2022. Fetal MRI findings were deemed "concordant" if they matched the ultrasound diagnosis.
Children (Basel)
January 2025
Department of Pediatrics, Division of Neonatology and Neonatal Intensive Medicine, University Hospital Centre Zagreb, 10000 Zagreb, Croatia.
Background/objectives: Cardiac rhabdomyoma (CR), the most frequently occurring fetal cardiac tumor, is often an early marker of tuberous sclerosis complex (TSC). This study evaluates outcomes of fetuses with prenatally diagnosed cardiac tumors managed at a single tertiary center.
Methods: Medical records of fetuses diagnosed with cardiac tumors between 2009 and 2024 were retrospectively reviewed.
Biomedicines
January 2025
Institute of Pathology "Dr. Ðorđe Joannović", Faculty of Medicine, University of Belgrade, 11000 Belgrade, Serbia.
Background: Congenital mesoblastic nephroma represents 3-10% of all pediatric renal tumors. With the advancement of ultrasound diagnostics and magnetic resonance imaging, the diagnosis of this renal neoplasm is increasingly being established prenatally and at birth. It usually presents as a benign tumor, but it can severely affect pregnancy outcomes, contributing to perinatal morbidity and mortality.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Arrow Program for Medical Research Education, Sheba Medical Center, Tel Hashomer, Ramat Gan 52621, Israel.
As medical imaging continues to expand, concerns about the potential risks of ionizing radiation to the developing fetus have led to a preference for non-radiation-based alternatives such as ultrasonography and fetal MRI. This review examines the current evidence on the safety of MRI during pregnancy, with a focus on 3 T MRI and contrast agents, aiming to provide a comprehensive synthesis that informs clinical decision-making, ensures fetal safety and supports the safe use of all available modalities that could impact management. We conducted a comprehensive review of studies from 2000 to 2024 on MRI safety during pregnancy, focusing on 3 T MRI and gadolinium use.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, SE1 7EH, UK.
Background: Motion correction methods based on slice-to-volume registration (SVR) for fetal magnetic resonance imaging (MRI) allow reconstruction of three-dimensional (3-D) isotropic images of the fetal brain and body. However, all existing SVR methods are confined to research settings, which limits clinical integration. Furthermore, there have been no reported SVR solutions for low-field 0.