Objective: To investigate the clinical application effect of the along-axis extraction method in the extraction of impacted mandibular third molars (IMTM) and to compare the biomechanical characteristics of different root extraction techniques through three-dimensional finite element analysis.
Methods: A total of 68 patients requiring IMTM extraction were enrolled and randomly divided into two groups: the experimental group underwent the along-axis extraction method, while the control group underwent the traditional buccal bone removal and root extraction method. The duration of the procedure, intraoperative and postoperative complications were recorded. Three-dimensional finite element analysis further revealed the stress distribution in the tooth root, jawbone, periodontal ligament, and mandibular canal during different root extraction methods.
Results: The duration of root extraction, pain score and swelling on the first postoperative day in the control group were (7.87±3.90) min, 4.62±1.90 and (11.37±5.12) mm, respectively, which were significantly higher than those in the experimental group [(5.74±2.37) min, 3.87±1.19 and (7.22±3.39) mm, respectively]. The root fracture rate and lingual bone plate fracture rate in the control group were significantly higher than those in the experimental group ( < 0.05). The results of finite element analysis showed that the control group ' s lingual al-veolar bone had the higher peak equivalent stress, and lingual bone plate fracture was prone to occur. The periodontal ligament of the experimental group had the higher equivalent stress value, making it more likely to rip and more likely to cause root displacement. When subjected to force, the experimental group' s instantaneous root displacement was higher, but the control group ' s root displacement was more pronounced in the lingual direction.
Conclusion: This study suggests that the along-axis extraction me-thod can not only effectively shorten the operative time but also reduce postoperative complications after extraction of impacted mandibular third molars, and enhance the safety of the operation and the patient' s comfort. Three-dimensional finite element analysis shows the biomechanical characteristics of various root extraction techniques visually, serves as a valuable guide for choosing and refining clinical surgical techniques, and confirms that extracting a tooth' s root along its long axis yields better clinical results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.19723/j.issn.1671-167X.2025.01.016 | DOI Listing |
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11759807 | PMC |
Sci Rep
January 2025
Department of Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.
View Article and Find Full Text PDFUltrasonics
January 2025
School of Information Science and Technology, Beijing University of Technology, Beijing 100124 China.
Carbon steel and low alloy steel are pearlitic heat-resistant steels with a lamellar microstructure. There are good mechanical properties and are widely used in crucial components of high-temperature pressure. However, long-term service in high-temperature environments can easily lead to material degradation, including spheroidization, graphitization, and thermal aging.
View Article and Find Full Text PDFJ Chromatogr A
January 2025
Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, EH9 3BF, United Kingdom.
Traditional packed beds in chromatography suffer from increased band broadening due to the random nature of packing, leading non-ideal fluid flow and channeling. To address these challenges, pillar array columns have been developed, offering improved performance over random packing thanks to their homogenous fluid profiles. The study aims to i) evaluate fluid dynamics and chromatographic performance across different PAC morphologies, ii) establish the influence of column morphology on performance, and iii) assess the correlation between chromatographic performance and hydrodynamic parameters.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
January 2025
Key Laboratory of Advanced Design and Simulation Techniques for Special Equipment, Ministry of Education, Hunan University, Changsha, China.
Total talus replacement has been demonstrated to increase ankle instability. However, no studies have explored how to enhance postoperative stability. This study aims to explore the effect of collateral ligament reconstruction on ankle stability by finite element analysis.
View Article and Find Full Text PDFPharmaceutics
January 2025
Department of Mathematical and Physical Sciences, Catholic University of Temuco, Temuco 4813302, Chile.
: A previous study investigated the in vitro release of methylene blue (MB), a widely used cationic dye in biomedical applications, from nanocellulose/nanoporous silicon (NC/nPSi) composites under conditions simulating body fluids. The results showed that MB release rates varied significantly with the nPSi concentration in the composite, highlighting its potential for controlled drug delivery. To further analyze the relationship between diffusion dynamics and the MB concentration, this study developed a finite element (FE) method to solve Fick's equations governing the drug delivery system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!