Background And Aim: Stent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.

Methods: Three minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models. Four weeks after EB-RFA, 10-mm diameter and 4-cm length MH-FCSEMSs were endoscopically inserted into the left intrahepatic bile duct of the models. Stent patency and migration, as well as adverse events including cholangitis and endoscopic stent removability, were assessed three months after stent placement. Additionally, clinical applications of MH-FCSEMS were performed in two patients with MHBO to determine feasibility, safety, and stent patency.

Results: MH-FCSEMSs were successfully inserted into the left main intrahepatic bile duct and common hepatic duct of the models under ERCP in all three animals without any technical difficulties. Cholangiograms performed 12 weeks after MH-FCSEMS placement showed no stent migration, and all were successfully removed from the animal models. The functional success rate, defined as a decrease in serum total bilirubin level of more than 50% at 12 weeks after stent placement, was 100%. Moreover, MH-FCSEMSs were successfully inserted in two patients with hilar cholangiocarcinoma. The procedures were technically feasible, and no major periprocedural complications were noted.

Conclusion: The preliminary long-term results of both preclinical and clinical pilot studies suggest that endoscopic biliary drainage using MH-FCSEMS may be a safe and effective treatment option for stenting and stent revision in the management of HBDO. Further studies comparing clinical outcomes to those of MH-FCSEMS without multi-hole in malignant hilar biliary obstruction will be needed to verify the clinical benefits.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10620-024-08810-1DOI Listing

Publication Analysis

Top Keywords

stent placement
16
bile duct
16
malignant hilar
12
hilar biliary
12
biliary obstruction
12
stent
10
fully covered
8
covered self-expandable
8
self-expandable metal
8
biliary drainage
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!