Cardiac digital twins (CDTs) offer personalized in-silico cardiac representations for the inference of multi-scale properties tied to cardiac mechanisms. The creation of CDTs requires precise information about the electrode position on the torso, especially for the personalized electrocardiogram (ECG) calibration. However, current studies commonly rely on additional acquisition of torso imaging and manual/semi-automatic methods for ECG electrode localization. In this study, we propose a novel and efficient topology-informed model to fully automatically extract personalized ECG standard electrode locations from 2D clinically standard cardiac MRIs. Specifically, we obtain the sparse torso contours from the cardiac MRIs and then localize the standard electrodes of 12-lead ECG from the contours. Cardiac MRIs aim at imaging of the heart instead of the torso, leading to incomplete torso geometry within the imaging. To tackle the missing topology, we incorporate the electrodes as a subset of the keypoints, which can be explicitly aligned with the 3D torso topology. The experimental results demonstrate that the proposed model outperforms the time-consuming conventional model projection-based method in terms of accuracy (Euclidean distance: 1.24±0.293 cm vs. 1.48±0.362 cm) and efficiency (2 s vs. 30-35 min). We further demonstrate the effectiveness of using the detected electrodes for in-silico ECG simulation, highlighting their potential for creating accurate and efficient CDT models. The code is available at https://github.com/lileitech/12lead_ECG_electrode_localizer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.media.2025.103472DOI Listing

Publication Analysis

Top Keywords

cardiac mris
16
12-lead ecg
8
ecg electrode
8
cardiac
8
cardiac digital
8
digital twins
8
contours cardiac
8
ecg
6
torso
6
personalized
4

Similar Publications

Cardiac digital twins (CDTs) offer personalized in-silico cardiac representations for the inference of multi-scale properties tied to cardiac mechanisms. The creation of CDTs requires precise information about the electrode position on the torso, especially for the personalized electrocardiogram (ECG) calibration. However, current studies commonly rely on additional acquisition of torso imaging and manual/semi-automatic methods for ECG electrode localization.

View Article and Find Full Text PDF

Practice patterns for acquiring neuroimaging after pediatric in-hospital cardiac arrest.

Resuscitation

January 2025

Division of Neurology, Department of Pediatrics, The Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, PA, USA.

Aims: To determine which patient and cardiac arrest factors were associated with obtaining neuroimaging after in-hospital cardiac arrest, and among those patients who had neuroimaging, factors associated with which neuroimaging modality was obtained.

Methods: Retrospective cohort study of patients who survived in-hospital cardiac arrest (IHCA) and were enrolled in the ICU-RESUS trial (NCT02837497).

Results: We tabulated ultrasound (US), CT, and MRI frequency within 7 days following IHCA and identified patient and cardiac arrest factors associated with neuroimaging modalities utilized.

View Article and Find Full Text PDF

Autograft dilation after Ross procedure in children and young adults is mitigated by autograft reinforcement: A retrospective MRI study.

Sci Rep

January 2025

Deutsches Herzzentrum der Charité, Department of Congenital and Pediatric Heart Surgery, Augustenburger Platz 1, 13353, Berlin, Germany.

Limited magnetic resonance imaging (MRI) data on autograft dilatation following the Ross procedure in congenital cohorts presents challenges in understanding its evolution and impact on clinical outcomes. This study, spanning from February 2003 to December 2022, included patients under 40 years at the time of the Ross procedure, with MRI follow-ups assessing dimensions at key aortic sites. Among 307 patients, 132 MRIs were analyzed from 76 individuals, revealing that autograft z-scores increase primarily with time post-procedure (Coef.

View Article and Find Full Text PDF

Urinary selenium, cranial MRI, and cognitive function in American Indians: The Strong Heart Study.

Environ Res

January 2025

Missouri Breaks Industries Research Inc, Eagle Butte, SD, USA; Department of Pathology, School of Medicine and Health Sciences, University of North Dakota, Grand Forks, ND, USA.

Introduction: Selenium (Se), a trace element found in soil and groundwater, is necessary for many biological functions, including cerebrovascular health, through selenoprotein formation. However, high concentrations may be harmful. American Indians face elevated cerebrovascular disease rates, which may be associated with other trace elements, such as Se.

View Article and Find Full Text PDF

Importance: Both sickle cell anemia (SCA) and socioeconomic status have been associated with altered brain structure and cognitive disability, yet precise mechanisms underlying these associations are unclear.

Objective: To determine whether brains of individuals with and without SCA appear older than chronological age and if brain age modeling using brain age gap (BAG) can estimate cognitive outcomes and mediate the association of socioeconomic status and disease with these outcomes.

Design, Setting, And Participants: In this cross-sectional study of 230 adults with and without SCA, individuals underwent brain magnetic resonance imaging (MRI) and cognitive assessment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!