Cardiovascular diseases (CVDs) were responsible for approximately 19 million deaths in 2020, marking an increase of 18.7% since 2010. Biological decellularized patches are common therapeutic solutions for CVD such as cardiac and valve defects. The preparation of biomaterials for cardiac patches involves two main processing methods: glutaraldehyde or photooxidation cross-linking (fixation) and noncross-linked (nonfixation) processing. Despite the variety of products available in the market, cardiac patches still suffer from significant limitations, failing to adequately mimic the properties of biological tissue and restore its function. This study assesses the impact of different processing methodologies on the biological and biomechanical outcomes of three commercially available cardiac patches (CorPatch, CardioCel, PhotoFix) and one newly developed decellularized cardiac patch (Adeka) when implanted as right ventricular outflow tract (RVOT) repair material on a rat model. Four different patches for cardiovascular repair were selected based on their processing approaches and included: photooxidation crosslinked (PhotoFix), glutaraldehyde crosslinked (CardioCel), noncross-linked small intestine submucosa (CorPatch) or enzyme, and hydrostatic pressure (Adeka) processed decellularized biomaterials. Structure and function were characterized prior to implantation via thickness mapping, cross-section morphology, 2D surface topography, 3D volume microstructure, biaxial testing, uniaxial tensile testing, ball burst, and suture retention. Their host-biomaterials response was assessed in vivo using a relevant model for cardiovascular repair: a rat (RVOT) reconstruction with 8 and 16-week timepoints. Topological analysis showed that the crosslinked cardiac patches had a more homogeneous thickness distribution when compared to the noncrosslinked patches. This agreed with histological evaluation, where cross-linking processed materials better preserved collagen content than noncrosslinked patches who were also more delaminated. Biaxial data demonstrated that all patches, except CorPatch, recapitulated the anisotropic behavior of healthy left ventricle tissue. The Adeka patch in-plane mechanics at 16 weeks was the one who better resembled the mechanics of healthy cardiac tissue. All patches showed appropriate biocompatibility and function at 8- and 16-week timepoints for RVOT patching. This included echocardiographic assessment, biomechanics, macrophage infiltration and polarization, and angiogenesis. Consistently with a more porous laminae structure, explants histology showed higher cell infiltration in non-crosslinked Adeka when compared to the crosslinked PhotoFix. Overall, both in vitro and in vivo tests indicate that the material processing does not impact the function, biomechanical performance, and the host response of the patches that can be considered as equally effective as materials based cardiac repair solutions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.35529DOI Listing

Publication Analysis

Top Keywords

cardiac patches
16
cardiovascular repair
12
patches
11
enzyme hydrostatic
8
hydrostatic pressure
8
processed decellularized
8
decellularized biomaterials
8
host response
8
ventricular outflow
8
model cardiovascular
8

Similar Publications

Several mutations of the uppermost arginine, R219, in the voltage-sensing sliding helix S4 of cardiac sodium channel Nav1.5 are reported in the ClinVar databases, but the clinical significance of the respective variants is unknown (VUSs). AlphaFold 3 models predicted a significant downshift of S4 in the R219C VUS.

View Article and Find Full Text PDF

Cardiovascular diseases (CVDs) were responsible for approximately 19 million deaths in 2020, marking an increase of 18.7% since 2010. Biological decellularized patches are common therapeutic solutions for CVD such as cardiac and valve defects.

View Article and Find Full Text PDF

Direct Axillary Artery Cannulation as Standard Perfusion Strategy in Minimally Invasive Coronary Artery Bypass Grafting.

J Cardiovasc Dev Dis

January 2025

Department of Cardiothoracic Surgery, Heart-Thorax Center, Klinikum Fulda, University Medicine Marburg, Campus Fulda, 36043 Fulda, Germany.

Objective: Cardiopulmonary bypass (CPB) via the right axillary artery (RAA) has become an alternative perfusion strategy, especially in complex aortic procedures. This study delineates our technique and outcome with direct axillary cannulation utilizing the Seldinger technique, which we adopted as the standard perfusion strategy in the sternum-sparing minimally invasive total coronary revascularization via left anterior thoracotomy (TCRAT) using CPB.

Methods: From November 2019 to December 2023, a total of 413 consecutive patients underwent nonemergent isolated coronary artery bypass grafting (CABG) via left anterior minithoracotomy on CPB with peripheral cannulation via the RAA and cardioplegic cardiac arrest, using this technique as a default strategy in the daily routine.

View Article and Find Full Text PDF

Spheroids serve as the building blocks for three-dimensional (3D) bioprinted tissue patches. When larger than 500 μm, the desired size for 3D bioprinting, they tend to have a hypoxic core with necrotic cells. Therefore, it is critical to assess the viability of spheroids in order to ensure the successful fabrication of high-viability patches.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!