In inertial confinement fusion experiments, hot spot mix caused by hydrodynamic instabilities is a critical performance limitation. Currently, multi-channel Ross filter pair imaging is used to quantitatively diagnose the mix mass of cryogenic hot spots driven by 100 kJ energy, but this method brings significant uncertainty. To measure the level of mix more accurately, we have developed a two-temperature model to modify the fitted bremsstrahlung spectra based on the characteristics of cryogenic implosion hot spots. In experiments with good symmetry of hot spots, fitting analysis of the radial distribution of electron temperature was conducted. Compared with traditional single-temperature models, the two-temperature modeling method is more sensitive to the radial distribution of electron temperature and provides new diagnostic insights into the spatial distribution of cryogenic hot spot mix.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0220582DOI Listing

Publication Analysis

Top Keywords

hot spot
16
cryogenic hot
12
spot mix
12
electron temperature
12
hot spots
12
multi-channel ross
8
ross filter
8
two-temperature model
8
radial distribution
8
distribution electron
8

Similar Publications

Transition metal oxides, distinguished by their high theoretical specific capacitance values, inexpensive cost, and low toxicity, have been extensively utilized as electrode materials for high-performance supercapacitors. Nevertheless, their conductivity is generally insufficient to facilitate rapid electron transport at high rates. Therefore, research on bimetallic oxide electrode materials has become a hot spot, especially in the field of micro-supercapacitors (MSC).

View Article and Find Full Text PDF

Introduction: Colorectal cancer (CRC) is the third most commonly diagnosed cancer in the United States (U.S.).

View Article and Find Full Text PDF

Studies have shown an association between colorectal cancer (CRC) sidedness and gene mutations that may affect CRC clinical behavior. This study examined the association between specific , , and hot-spot mutations and primary CRC sidedness. We performed a retrospective cohort analysis of 722 patients diagnosed with primary CRC and tested for , , and hot-spot mutations at the University of Texas Medical Branch (UTMB) from January 2016 through July 2023.

View Article and Find Full Text PDF

Bulk thermally conductive polyethylene as a thermal interface material.

Mater Horiz

January 2025

Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York 14853, USA.

As the demand for high-power-density microelectronics rises, overheating becomes the bottleneck that limits device performance. In particular, the heterogeneous integration architecture can magnify the importance of heat dissipation and necessitate electrical insulation between critical junctions to prevent dielectric breakdown. Consequently, there is an urgent need for thermal interface materials (TIMs) with high thermal conductivity and electrical insulation to address this challenge.

View Article and Find Full Text PDF

In inertial confinement fusion experiments, hot spot mix caused by hydrodynamic instabilities is a critical performance limitation. Currently, multi-channel Ross filter pair imaging is used to quantitatively diagnose the mix mass of cryogenic hot spots driven by 100 kJ energy, but this method brings significant uncertainty. To measure the level of mix more accurately, we have developed a two-temperature model to modify the fitted bremsstrahlung spectra based on the characteristics of cryogenic implosion hot spots.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!