Detection and segmentation of brain abnormalities using Magnetic Resonance Imaging (MRI) is an important task that, nowadays, the role of AI algorithms as supporting tools is well established both at the research and clinical-production level. While the performance of the state-of-the-art models is increasing, reaching radiologists and other experts' accuracy levels in many cases, there is still a lot of research needed on the direction of in-depth and transparent evaluation of the correct results and failures, especially in relation to important aspects of the radiological practice: abnormality position, intensity level, and volume. In this work, we focus on the analysis of the segmentation results of a pre-trained U-net model trained and validated on brain MRI examinations containing four different pathologies: Tumors, Strokes, Multiple Sclerosis (MS), and White Matter Hyperintensities (WMH). We present the segmentation results for both the whole abnormal volume and for each abnormal component inside the examinations of the validation set. In the first case, a dice score coefficient (DSC), sensitivity, and precision of 0.76, 0.78, and 0.82, respectively, were found, while in the second case the model detected and segmented correct (True positives) the 48.8% (DSC ≥ 0.5) of abnormal components, partially correct the 27.1% (0.05 > DSC > 0.5), and missed (False Negatives) the 24.1%, while it produced 25.1% False Positives. Finally, we present an extended analysis between the True positives, False Negatives, and False positives versus their position inside the brain, their intensity at three MRI modalities (FLAIR, T2, and T1ce) and their volume.

Download full-text PDF

Source
http://dx.doi.org/10.3390/jimaging11010006DOI Listing

Publication Analysis

Top Keywords

true positives
8
false negatives
8
false positives
8
exploring multi-pathology
4
brain
4
multi-pathology brain
4
segmentation
4
brain segmentation
4
segmentation volume-based
4
volume-based component-based
4

Similar Publications

Reusable Biosensor for Easy RNA Detection from Unfiltered Saliva.

Sensors (Basel)

January 2025

Department of Clinical and Molecular Biochemistry, Pomeranian Medical University in Szczecin, 72 Powstańców Wlkp. Al., 70-111 Szczecin, Poland.

Biosensors are transforming point-of-care diagnostics by simplifying the detection process and enabling rapid, accurate testing. This study introduces a novel, reusable biosensor designed for direct viral RNA detection from unfiltered saliva, targeting SARS-CoV-2. Unlike conventional methods requiring filtration, our biosensor leverages a unique electrode design that prevents interference from saliva debris, allowing precise measurements.

View Article and Find Full Text PDF

Background: Extreme hemodynamic changes, especially intraoperative hypotension (IOH), are common and often prolonged during Liver Transplant (LT) surgery and during initial hours of recovery. Hypotension Prediction Index (HPI) software is one of the tools which can help in proactive hemodynamic management. The accuracy of the advanced hemodynamic parameters such as Cardiac Output (CO) and Systemic Vascular Resistance (SVR) obtained from HPI software and prediction performance of the HPI in LT surgery remains unknown.

View Article and Find Full Text PDF

Purpose: Pneumonia, respiratory failure, and fracture are common and highly burdensome for adults with cerebral palsy (CP). To date, there are no clinically friendly tools to assess individualized risk of these outcomes for adults with CP. The objective was to develop and validate prognostic models for 5-year risk of pneumonia, respiratory failure/collapse, and fracture for adults with CP.

View Article and Find Full Text PDF

Decline in global biodiversity intactness over the past two decades.

Sci Total Environ

January 2025

School of Artificial Intelligence, Anhui University, Hefei 230601, China.

Knowledge of the dynamics of biodiversity intactness and its spatial differentiation over different geographic regions of the world is crucial for the improved design of effective biodiversity conservation strategies. However, comprehensive investigations of the multiple indicators of biodiversity intactness across several spatial scales are lacking. The current study used an annual time series (2000-2020) of the biodiversity intactness index (BII) to investigate the mean magnitude, temporal trajectory, and relative changes in biodiversity intactness at the national, regional, and global levels.

View Article and Find Full Text PDF

Background: Due to scientific advancements in high-throughput data production technologies, omics studies, such as genomics and metabolomics, often give rise to numerous measurements per sample/subject containing several noisy variables that potentially cloud the true signals relevant to the desired study outcome(s). Therefore, correcting for multiple testing is critical while performing any statistical test of significance to minimize the chances of false or missed discoveries. Such correction practice is commonplace in genome-wide association studies (GWAS) but is also becoming increasingly relevant to metabolome-wide association studies (MWAS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!