We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included. Accuracy was assessed by comparison with LVO. Intra- and inter-observer reproducibility of the off-line analysis were assessed. Forty-five neonates were included. RVO calculation with tip-PVD was more accurate than hinge-PVD in comparison with LVO, r 0.712 versus 0.464, bias (95% limits of agreement) 1.4 mL/kg/min (-26-29 mL/kg/min) versus 61 mL/kg/min (-11-132 mL/kg/min), respectively. Both hinge-PVD and tip-PVD presented similar reproducibility, with an intra-observer bias (95% LOA) of 0.3 (-1.0-0.5) and -0.2 (-0.8-0.5) respectively, and an inter-observer bias of 0.1 (-1.3-1.6) and 0.1 (-1.4-1.6). RVO calculation using tip-PVD was more accurate than the conventional technique, with similar reproducibility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/jcdd12010018 | DOI Listing |
Biomedicines
December 2024
Ludwig Boltzmann Institute for Cardiovascular Research, Center for Biomedical Research and Translational Surgery, Medical University of Vienna, 1090 Vienna, Austria.
Previously, we showed that blood-based polarizing cardioplegia exerted beneficial cardioprotection during hypothermic ischemia; however, these positive effects of blood-based polarizing cardioplegia were reduced during normothermic ischemia compared to blood-based hyperkalemic (depolarizing) cardioplegia. This study compares crystalloid polarizing cardioplegia to crystalloid depolarizing cardioplegia in a normothermic porcine model of cardiopulmonary bypass; Methods: Twelve pigs were randomized to receive either normothermic polarizing ( = 7) or depolarizing ( = 5) crystalloid cardioplegia. After the initiation of cardiopulmonary bypass, normothermic arrest (34 °C, 60 min) was followed by 60 min of on-pump and 90 min of off-pump reperfusion.
View Article and Find Full Text PDFAm J Obstet Gynecol
January 2025
Harris Birthright Research Centre for Fetal Medicine, Fetal Medicine Research Institute, King's College Hospital, London, UK; School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Background: The role of maternal cardiac and hemodynamic assessment during normal and complicated pregnancies has gained attention during the last few years. Some researchers suggested that the manifestation of complications in pregnancy suffering from impaired placentation is mainly driven by pre-existing cardiac changes, identifiable at an early stage by echocardiographic and hemodynamic assessment. It is therefore of great importance to determine the link between placental perfusion and maternal cardiac function and hemodynamics.
View Article and Find Full Text PDFASAIO J
January 2025
Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Palo Alto, California.
The use of an alteplase (Activase) purge solution to address Impella ventricular assist device "thrombosis" or "purge system occlusion" has been mainly documented with earlier generation Impella devices (CP, 2.5, 5.0).
View Article and Find Full Text PDFEchocardiography
January 2025
Cardiology Department, Unidade Local de Saúde do Alto Ave, Guimarães, Portugal.
Purpose: This study explores the effects of anthracycline chemotherapy (AC) on breast cancer patients, focusing on changes in body composition, advanced echocardiographic parameters at rest and during exercise, and biomarkers; and subsequently assesses whether these parameters are associated with impaired cardiorespiratory fitness (CRF).
Methods: In this prospective study, we evaluated women with early-stage breast cancer undergoing AC at three visits: before AC, 1 month after, and 6 months post-AC.
Results: The study included 32 women with breast cancer, with functional disability increasing from 9.
J Cardiovasc Dev Dis
January 2025
Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, 37126 Verona, Italy.
We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!