Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4103/aca.aca_160_24 | DOI Listing |
Ann Card Anaesth
January 2025
Department of Cardiac Anaesthesia, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
Ann Card Anaesth
January 2025
Department of Onco-Anesthesiology and Palliative Medicine, DRBRAIRCH, AIIMS, New Delhi, India.
Ann Card Anaesth
January 2025
Department of Cardiothoracic and Vascular Anaesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, India.
Background: This study aimed to assess the accuracy of tricuspid spectral Doppler (E/A) and tissue Doppler parameters (E/E') to diagnose right ventricular diastolic dysfunction (RVDD) in comparison to American Society of Echocardiography (ASE criteria) in pediatric tetralogy of Fallot (TOF) patients after surgical repair.
Methods: This prospective, observational study was done at a tertiary care hospital involving 40 pediatric TOF patients aged less than 2 years who underwent complete intracardiac repair with cardiopulmonary bypass (CPB). Echocardiographic observations were made using a pediatric transesophageal echocardiography probe after surgical repair in the post-CPB period.
Medicina (Kaunas)
December 2024
Machine & Hybrid Intelligence Lab, Department of Radiology, Northwestern University, 737 N. Michigan Avenue Suite 1600, Chicago, IL 60611, USA.
: Studies have shown that inflammation markers can be used as prognostic tools in predicting acute ischemic stroke. In this study, we conducted a comparison of several inflammation scores in predicting left atrial thrombosis (LAT) in patients with ischemic stroke without AF. : In this single-center, retrospective study, we included 303 consecutive patients with ischemic stroke.
View Article and Find Full Text PDFCardiovasc Interv Ther
December 2024
Department of Cardiology and Cardiovascular Research Institute Basel (CRIB), University Hospital Basel, University of Basel, Petersgraben 4, 4031, Basel, Switzerland.
Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!