Application of fibrin sealant in drain-free transoral endoscopic thyroidectomy vestibular approach.

Tzu Chi Med J

Department of Otolaryngology, Head and Neck Surgery, Taichung Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taichung, Taiwan.

Published: August 2024

Objective: The transoral endoscopic thyroidectomy vestibular approach (TOETVA) is a minimally invasive technique. This study aimed to compare the safety of TOETVA with fibrin sealant (Tisseel) and TOETVA with drainage.

Materials And Methods: Patients who underwent TOETVA between January 2018 and December 2021 were divided into drainage ( = 20) and Tisseel ( = 30) groups.

Results: The primary outcome was the incidence of complications. The secondary outcomes were operative time and postoperative pain. There were no significant differences in patient demographics, tumor size, intraoperative blood loss, and hospitalization days between the two groups. No patient required conversion to open thyroidectomy. The incidence of complications and postoperative pain was similar in the two groups. The operative time for TOETVA with Tisseel was significantly shorter than for TOETVA with drainage ( = 0.038).

Conclusion: TOETVA with Tisseel is a safe alternative to TOETVA with drainage, having a short operative time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11753525PMC
http://dx.doi.org/10.4103/tcmj.tcmj_41_24DOI Listing

Publication Analysis

Top Keywords

operative time
12
fibrin sealant
8
transoral endoscopic
8
endoscopic thyroidectomy
8
thyroidectomy vestibular
8
vestibular approach
8
toetva
8
incidence complications
8
postoperative pain
8
toetva tisseel
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!