Screening for inborn metabolic disorders (IMDs) in newborns is an important way to prevent serious metabolic and developmental difficulties that can result in lasting disabilities or even death. Electrospray ionization tandem mass spectrometry (MS/MS) provides an efficacious newborn blood spot screening (NBS) mechanism for analyzing dried blood spot specimens (DBSs) for biochemical markers for these conditions. Where possible, the elimination of derivatization in specimen preparation can simplify and streamline analysis. The Paya Hamsan Technologies Underivatized Newborn Screening Assay (PHUNSA) is an underivatized MS/MS test kit for IMD NBS. Validation of the accuracy, precision, linearity, and stability was based on the ISO 15189 standard and the CLSI NBS04 guideline. The PHUNSA kit demonstrated suitable performance along with acceptable recovery rates and negligible bias for many IMD analytes. Assay sensitivity was demonstrated through acceptable limits of detection (LOD) and lower limits of quantification (LLOQ). Specimen preparation times were decreased, the coefficients of variation were consistently below 10%, and accuracy and stability were demonstrated under various testing conditions, including prolonged storage and transportation. The PHUNSA kit provides a simplified, efficient, and reliable approach to IMD NBS with the potential to enhance NBS in Iran and other locations by providing a scalable, cost-effective, and streamlined option for early IMD detection and management.

Download full-text PDF

Source
http://dx.doi.org/10.3390/ijns11010004DOI Listing

Publication Analysis

Top Keywords

blood spot
12
paya hamsan
8
hamsan technologies
8
technologies underivatized
8
underivatized newborn
8
newborn screening
8
screening assay
8
assay phunsa
8
inborn metabolic
8
metabolic disorders
8

Similar Publications

Spinal muscular atrophy (SMA) is a degenerative neuromuscular condition resulting from a homozygous deletion of the survival motor neuron 1 () gene in 95% of patients. A timely diagnosis via newborn screening (NBS) and initiating treatment before the onset of symptoms are critical for improving health outcomes in affected individuals. We carried out a screening test by quantitative PCR (qPCR) to amplify the exon seven of using dried blood spot (DBS) samples.

View Article and Find Full Text PDF

Screening for inborn metabolic disorders (IMDs) in newborns is an important way to prevent serious metabolic and developmental difficulties that can result in lasting disabilities or even death. Electrospray ionization tandem mass spectrometry (MS/MS) provides an efficacious newborn blood spot screening (NBS) mechanism for analyzing dried blood spot specimens (DBSs) for biochemical markers for these conditions. Where possible, the elimination of derivatization in specimen preparation can simplify and streamline analysis.

View Article and Find Full Text PDF

Identifying sex from an unknown dried blood spot (DBS), especially when the corpse remains undiscovered, often provides valuable evidence in forensic casework. While DNA-based sex determination is a reliable method in forensic settings, it requires expensive reagents and is time-consuming. To develop a rapid reagent-free blood test for sex, we employed paper spray ionization mass spectrometry (PSI-MS) to capture sex-discriminatory lipid profiles from 200 DBS samples comprising 100 males and 100 females.

View Article and Find Full Text PDF

Haplotypes of Chloroquine Resistance Marker Genes Among Uncomplicated Malaria Cases in Lagos, Nigeria.

Biochem Genet

January 2025

Key Laboratory of Parasite and Vector Biology of the Chinese Ministry of Health, Chinese Center for Disease Control and Prevention, WHO Collaborating Centre for Tropical Diseases, National Institute of Parasitic Diseases, Shanghai, 200025, People's Republic of China.

Drug resistance resulting from mutations in Plasmodium falciparum, that caused the failure of previously effective malaria drugs, has continued to threaten the global malaria elimination goal. This study describes the profiles of P. falciparum chloroquine resistance transporter (Pfcrt) and P.

View Article and Find Full Text PDF

Background: The main technique for identification of free flap perforator vessels is Doppler sonography, which is not always accurate, user dependent and affected by the patient's body habitus.

Methods: Adult patients undergoing head and neck resection and free flap reconstruction at two academic institutions were enrolled. Doppler sonography was used to identify perforators, and were marked using a skin marker.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!