Background: This study aimed to investigate the safety and reliability of using bioabsorbable screws for the fixation of chevron osteotomy in the treatment of hallux valgus (HV) deformity.

Methods: Clinical cases of chevron osteotomy in the treatment of HV deformities in our hospital between December 2018 and August 2022 were retrospectively summarised to compare preoperative imaging indices with those at the final follow-up session, including the hallux valgus angle (HVA), intermetatarsal angle (IMA) and tibial sesamoid position (TSP). The American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal scale, short-form health survey questionnaire (SF-36) and European Foot and Ankle Society (EFAS) scale were used to assess therapeutic efficacy. The visual analogue scale (VAS) was used to assess pain relief. Moreover, complications were recorded.

Results: Twenty-six patients (39 feet) were included, and the mean follow-up period was 24.0 months. No infection, delayed healing or non-healing was recorded. The osteotomy ends healed well without non-union or delayed union. Four cases of recurrence (HVA ≥20°), two of numbness in the distal toe, one of necrosis of the first metatarsal head and one of osteoarthritis of the first metatarsophalangeal joint occurred. No patients underwent secondary surgery. The HVA, IMA and TSP significantly reduced at the final follow-up session compared with their preoperative values, and significant improvement was seen in clinical scores.

Conclusion: The use of bioabsorbable screws for the fixation of chevron osteotomy is safe and effective in the treatment of HV deformities.

Download full-text PDF

Source
http://dx.doi.org/10.7547/24-043DOI Listing

Publication Analysis

Top Keywords

chevron osteotomy
16
bioabsorbable screws
12
screws fixation
12
fixation chevron
12
osteotomy treatment
12
hallux valgus
12
treatment hallux
8
treatment deformities
8
final follow-up
8
follow-up session
8

Similar Publications

Background: This study aimed to investigate the safety and reliability of using bioabsorbable screws for the fixation of chevron osteotomy in the treatment of hallux valgus (HV) deformity.

Methods: Clinical cases of chevron osteotomy in the treatment of HV deformities in our hospital between December 2018 and August 2022 were retrospectively summarised to compare preoperative imaging indices with those at the final follow-up session, including the hallux valgus angle (HVA), intermetatarsal angle (IMA) and tibial sesamoid position (TSP). The American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal scale, short-form health survey questionnaire (SF-36) and European Foot and Ankle Society (EFAS) scale were used to assess therapeutic efficacy.

View Article and Find Full Text PDF

Researchers have modified PLA materials to enhance their mechanical properties and meet the clinical requirements. However, the strength and stiffness of PLA are still significantly lower than those of metals. Building on the established chevron clinical procedure and considering the mechanical characteristics of PLA screws, we devised a modified chevron osteotomy (MCO) based on a load-reducing structure with the aim of reducing the load on the screws.

View Article and Find Full Text PDF

: Hallux valgus is a common forefoot disorder with hundreds of proposed management techniques. Distal chevron osteotomy with a modified McBride procedure has been traditionally recommended for mild hallux valgus because of its simple and less invasive nature with fewer complications, faster recovery, and reliable outcomes. In recent years, the indications for this procedure have expanded to include hallux valgus with severe deformities.

View Article and Find Full Text PDF

Relationship between proximal to distal phalangeal articular angle and Hallux Pronation in Hallux Valgus deformity.

Sci Rep

January 2025

Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.

This study aimed to determine whether hallux pronation influences the proximal to distal phalangeal articular angle (PDPAA) and evaluate its relationship with postoperative recurrence. We included 94 hallux valgus (HV) patients who underwent distal chevron metatarsal osteotomy (DCMO) alone (DCMO-only group, n = 15) and DCMO with Akin osteotomy (DCMO + Akin group, n = 79). Preoperative additional toe radiographs were taken under supination stress to position the pronated toe as a true anteroposterior orientation.

View Article and Find Full Text PDF

Purpose: Olecranon osteotomy has been associated with loss of reduction, nonunion, implant failure, and migration of wires. We aim to evaluate quality of reduction of the osteotomy site as a predictor of olecranon osteotomy nonunion.

Methods: One hundred and twenty-five distal humerus fractures that underwent open reduction internal fixation (ORIF) were reviewed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!