Background: Although hearing loss in orthopaedic surgeons from exposure to hammering sounds have been previously reported, there are no reports on the noise environment during total hip arthroplasty (THA) in Japan. The aim of this study was to investigate the sound level generated by cementless THA in Japan, and to discuss the broader sound environment within this space.

Methods: 94 cementless THAs (94 patients with informed consent) performed by four surgeons were included. The equivalent continuous A-weighted sound levels (LAeq) in a series of 1086 continuous hammering maneuvers without pause and the maximum C-weighted sound levels (LCpeak) in 17,210 hammering sounds were investigated.

Results: Among the hammering sounds analysed in terms of LAeq, the sound pressure level associated with some procedures did result in non-scrubbed personnel being exposed to the 8-h sound levels exceeding the LAeq threshold (85 dB), while most procedures exceeded this threshold for scrubbed personnel. For scrubbed personnel, the maximum number of operations that could be safely attended per day were 16.1 and 1.6 operations under average and worst-case scenario conditions, respectively. For LCpeak, no sound was found to be above the threshold (135 dB) for either non-scrubbed or scrubbed personnel.

Conclusions: Although average sound levels in a standard operating theatre during cementless THA did not exceed recommended thresholds among non-scrubbed medical practitioners, our data are not sufficient to conclude that the sound environment is safe for scrubbed personnel close to the sound source. Further investigation is needed regarding sound exposure and the occurrence of hearing impairment in surgeons who perform total hip arthroplasties.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jos.2024.12.007DOI Listing

Publication Analysis

Top Keywords

sound levels
20
sound
12
total hip
12
hammering sounds
12
scrubbed personnel
12
operating theatre
8
hip arthroplasty
8
tha japan
8
cementless tha
8
sound environment
8

Similar Publications

Noise-induced hearing loss is one of the most common forms of hearing loss in adults and also one of the most common occupational diseases. Extensive previous work has shown that the highly sensitive synapses of the inner hair cells (IHCs) may be the first target for irreparable damage and permanent loss in the noise-exposed cochlea, more precisely in the cochlear base. However, how such synaptic loss affects the synaptic physiology of the IHCs in this particularly vulnerable part of the cochlea has not yet been investigated.

View Article and Find Full Text PDF

Sound levels in the operating theatre resulting from hammering during cementless total hip arthroplasty.

J Orthop Sci

January 2025

Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, 2-1-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan; Department of Orthopaedics, Faculty of Medicine, Juntendo University, 2-1-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan.

Background: Although hearing loss in orthopaedic surgeons from exposure to hammering sounds have been previously reported, there are no reports on the noise environment during total hip arthroplasty (THA) in Japan. The aim of this study was to investigate the sound level generated by cementless THA in Japan, and to discuss the broader sound environment within this space.

Methods: 94 cementless THAs (94 patients with informed consent) performed by four surgeons were included.

View Article and Find Full Text PDF

In everyday hearing, listeners face the challenge of understanding behaviorally relevant foreground stimuli (speech, vocalizations) in complex backgrounds (environmental, mechanical noise). Prior studies have shown that high-order areas of human auditory cortex (AC) pre-attentively form an enhanced representation of foreground stimuli in the presence of background noise. This enhancement requires identifying and grouping the features that comprise the background so they can be removed from the foreground representation.

View Article and Find Full Text PDF

Ethnopharmacological Relevance: Xiao'er Feike Granules (XFG) is an approved and widely used classical Chinese medicine prescription for the treatment of pediatric respiratory diseases. Extensive clinical studies have reported that XFG demonstrates high efficacy and minimal adverse reactions in treating acute bronchitis (AB). However, there is an urgent need for a more cohesive evaluation of the evidence regarding the safe clinical use of XFG for AB.

View Article and Find Full Text PDF

Introduction: Assessing the severity of kinetic tremor is important in clinical and research settings. Archimedes spirals are often used to assess tremor severity. Rating tremor from spirals has been based solely on visual information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!