Evaluating the Effect of Various Pure Tone Averages on Cochlear Implant Candidacy Screening.

Laryngoscope

Department of Otolaryngology - Head and Neck Surgery, University of Washington, Seattle, Washington, USA.

Published: January 2025

Objective: To provide evidence to use an extended frequency pure tone average to screen for cochlear implant evaluation candidates as recommended by the American Cochlear Implant Alliance. Additionally, to determine whether traditional low frequency, high or low frequency, high frequency, or extended frequency pure tone average most accurately predicts cochlear implant candidates based on speech perception scores from aided AzBio sentence testing or aided consonant-nucleus-consonant (CNC) testing.

Method: Adults from a tertiary care center who completed aided sentence testing during cochlear implant evaluation between 2014 and 2024 were assessed. Pure tone averages at low, high, low or high, and extended frequency ranges were evaluated with individual ear's aided AzBio or aided CNC scores as an outcome. Sensitivity, specificity, negative predictive value, and positive predictive value were assessed and compared using a paired study design.

Results: There were 675 observations from 363 patients with AzBio as an outcome variable and 665 observations from 364 patients with CNC scores as an outcome variable. High or low frequency achieved the highest sensitivity at 96.3% AzBio as an outcome and 95.6% with CNC as an outcome, which was significantly better than low frequency (p < 0.001). Low frequency achieved the best specificity at 63.6% with AzBio as an outcome 76.9% with CNC as an outcome.

Conclusion: Extended frequency pure tones resulted in greater sensitivity in predicting CI candidates compared with the traditionally used low frequency pure tone average. Screening with wider frequency values will lead to a greater number of patients being identified for a cochlear implant evaluation.

Level Of Evidence: Level 3 Laryngoscope, 2025.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lary.32018DOI Listing

Publication Analysis

Top Keywords

cochlear implant
20
pure tone
16
low frequency
16
extended frequency
12
high low
12
tone averages
8
frequency
8
frequency pure
8
tone average
8
implant evaluation
8

Similar Publications

Can a Cochlear Implant Be Used as an Electrical Impedance Tomography Device?

Int J Numer Method Biomed Eng

January 2025

Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Gauteng, South Africa.

The imaging of the live cochlea is a challenging task. Regardless of the quality of images obtained from modern clinical imaging techniques, the internal structures of the cochlea mainly remain obscured. Electrical impedance tomography (EIT) is a safe, low-cost alternative medical imaging technique with applications in various clinical scenarios.

View Article and Find Full Text PDF

Objective: To provide evidence to use an extended frequency pure tone average to screen for cochlear implant evaluation candidates as recommended by the American Cochlear Implant Alliance. Additionally, to determine whether traditional low frequency, high or low frequency, high frequency, or extended frequency pure tone average most accurately predicts cochlear implant candidates based on speech perception scores from aided AzBio sentence testing or aided consonant-nucleus-consonant (CNC) testing.

Method: Adults from a tertiary care center who completed aided sentence testing during cochlear implant evaluation between 2014 and 2024 were assessed.

View Article and Find Full Text PDF

Background: The intraoperative measurements are essential steps in cochlear implant (CI) surgery for confirming correct electrode placement.

Objectives: To examine the intraoperative impedance and electrically evoked action potential (ECAP) measurement results of cochlear implant (CI) users with normal cochlear anatomy (NCA) and to compare them with CI users with inner ear malformations (IEM).

Material And Methods: This retrospective study included intraoperative data of 300 ears from 258 individuals using Medel and Cochlear (Nucleus) CI devices.

View Article and Find Full Text PDF

Background: This investigation quantifies the mean and median hearing thresholds and assesses the prevalence of age-related hearing loss within the senior population of Taipei.

Methods: In a substantive geriatric assessment supported by government initiative, 1696 individuals from a community hospital partook in this cross-sectional study (2016-2018). Detailed audiometric evaluations logged pure-tone thresholds across critical frequencies (0.

View Article and Find Full Text PDF

Objective: Measuring listening effort using pupillometry is challenging in cochlear implant (CI) users. We assess three validated speech tests (Matrix, LIST, and DIN) to identify the optimal speech material for measuring peak-pupil-dilation (PPD) in CI users as a function of signal-to-noise ratio (SNR).

Design: Speech tests were administered in quiet and two noisy conditions, namely at the speech recognition threshold (0 dB re SRT), i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!