Background: Ozurdex® (Allergan®, AbbVie Company, North Chicago, Illinois, EUA), is composed of 0.7 mg of dexamethasone, fused in a solid biodegradable PLGA polymer, whose degradation occurs naturally in the vitreous cavity, usually in six months after its application.
Methods: In this study, we included patients aged ≥ 18 years with one or two eyes who had an indication for Ozurdex implants. Eyes submitted to Ozurdex application were evaluated in the first hour after the injection via transpalpebral contact B-scan ocular ultrasonography (Aviso® or Compact Touch, Quantel) and non-mydriatic ultra-widefield fundus photography (California, Optos) performed sequentially. The exams were executed using similar parameters and techniques, by the same ophthalmologist, after every 45 days, until the end of 180 days. The programed visits were the initial (tagged D0) and sequential (D45, D90, D135, and D180) visits, with a possible variance of seven days, before or after. The ultrasonographic Ozurdex findings evaluated were: non-quantitative: structure, height, reflectivity, artifact production, location, and movement; and quantitative: length and thickness. Ultra-widefield fundus photography parameters were: Ozurdex visualization, location, and structure.
Results: The B-scan showed the implant initially, at the D0 visit, as a well-delimited and homogeneously highly reflective linear and continuous structure. On D45, Ozurdex implants presented with low internal reflectivity and irregularity in the limits. On D90, D135, and D180, reductions in the length and thickness progressively lessened, leading to the final appearance of a small highly reflective clust. Over time, all the implants presented reductions in length and thickness. The mean length at D0 was 7.42 ± 0.39 mm and at the final visit (D180) it was 1.50 ± 0.47 mm. The mean thickness at D0 was 0.77 ± 0.13 mm and at the final visit (D180) it was 0.44 ± 0.18 mm.
Conclusions: Considering implant dimensions, the change in length over time was more evident than the change in thickness. In all the cases where visualization was possible, positive correlations with B-scan findings were found despite changes in patient position. These alterations evidenced in the Ozurdex® implant over time may be related to the degradation of the glucose polymer structure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1186/s40942-024-00625-6 | DOI Listing |
Int J Retina Vitreous
January 2025
Department of Ophthalmology and Visual Sciences, Federal University of São Paulo (UNIFESP), Rua Botucatu, 822, Vila Clementino, São Paulo/SP, 04023-062, Brazil.
Background: Ozurdex® (Allergan®, AbbVie Company, North Chicago, Illinois, EUA), is composed of 0.7 mg of dexamethasone, fused in a solid biodegradable PLGA polymer, whose degradation occurs naturally in the vitreous cavity, usually in six months after its application.
Methods: In this study, we included patients aged ≥ 18 years with one or two eyes who had an indication for Ozurdex implants.
Transl Vis Sci Technol
January 2025
Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA, USA.
Purpose: To compare the assessment of clinically relevant retinal and choroidal lesions as well as optic nerve pathologies using a novel three-wavelength ultra-widefield (UWF) scanning laser ophthalmoscope with established retinal imaging techniques for ophthalmoscopic imaging.
Methods: Eighty eyes with a variety of retinal and choroidal lesions were assessed on the same time point using Topcon color fundus photography (CFP) montage, Optos red/green (RG), Heidelberg SPECTRALIS MultiColor 55-color montage (MCI), and novel Optos red/green/blue (RGB). Paired images of the optic nerve, retinal, or choroidal lesions were initially diagnosed based on CFP imaging.
Photodiagnosis Photodyn Ther
December 2024
Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China; Beijing Ophthalmology and Visual Science Key Laboratory, Beijing 100730, China. Electronic address:
Purpose: To investigate retinal vascular abnormalities in the affected and fellow eyes of children with Coats' disease using Optos® ultra-widefield fundus fluorescein angiography (UWFFA) and compare the peripheral vascular abnormalities between fellow eyes and normal control eyes.
Methods: Children diagnosed with Coats' disease who underwent UWFFA were retrospectively reviewed. Healthy eyes with complete UWFFA data were selected as controls.
BMC Ophthalmol
December 2024
Department of Ophthalmology, First Affiliated Hospital of Xi'an Jiaotong University, Yanta Road, Xi'an, Shaanxi, 710061, China.
Background: This study was to evaluate the features of choroidal Sattler's and Haller's layer (CSHL) vessels in adults and explore its relationship with factors such as age, axial length (AL) and body mass index (BMI) by using ultra-widefield swept-source optical coherence tomography angiography (ultra-widefield SS-OCTA).
Methods: 24mm × 20mm fovea centered rectangular SS-OCTA scans were acquired. They were divided into 9 identical grids, with each equal size of 8 mm × 6.
Background: Variants in CRX are associated with dominantly inherited retinopathy with considerable phenotypic variability. Many patients have central retinal degeneration; in some patients, we have observed an additional focus of degeneration in the nasal retina. This study explores this phenotypic association amongst patients with CRX-associated disease.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!