Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.
Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study. Standard anteroposterior radiographs were obtained postoperatively using C-arm fluoroscopy. A 3D-2D image matching method was used to measure the femoral component varus/valgus angle and internal/external rotation (IR/ER) relative to the tibial component. The bearing position parameters were measured. Patients were divided into varus/valgus and IR/ER groups according to the femoral component varus/valgus and IR/ER angles. The bearing position parameters of each group were compared separately.
Results: There were 57 patients in the varus group, 63 in the valgus group, 59 in the IR group, and 61 in the ER group. The distance between the bearing lateral edge and the lateral wall of the tibial component (W-BED) was significantly lower in the varus group than the valgus group (1.9 [0-6.4] vs. 2.8 [0.3-7.7] mm; P < 0.001). No differences were detected in any bearing position parameters. The varus/valgus angle of the femoral component showed a significant negative correlation with the W-BED. The IR/ER angle of the femoral component showed no significant correlation with any of the positional parameters.
Conclusions: Implantation of femoral component with varus/valgus angle relative to tibial component can cause the bearing to deviate from the planned position. If the varus/valgus angle exceeds 8° it can cause the bearing to hit or away from the lateral wall of the tibial component, resulting in an increased risk of dislocation of the bearing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1186/s12891-025-08292-w | DOI Listing |
Cureus
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.
Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, People's Republic of China.
Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.
Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study.
Medicine (Baltimore)
January 2025
Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey.
Anterior cruciate ligament reconstruction aims to improve knee stability and range of motion. The AperFix system consists of polymer components, and fixed-loop fixation is an established endoscopic technique. Our aim in this study was to compare the long-term clinical and radiological results of AperFix and fixed-loop fixation and to prove that the long-term results of the AperFix fixation method are at least as good as those of the fixed loop device.
View Article and Find Full Text PDFHip Int
January 2025
Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Introduction: Total hip arthroplasty (THA) is widely used for active, elderly patients with femoral neck fractures (FNF). Compared to THA for osteoarthritis, THA for FNF is associated with a higher incidence of dislocation and reoperation. Robotic assistance may improve component positioning and leg-length restoration in THA, but its use in FNF has not been described.
View Article and Find Full Text PDFOrthop Surg
January 2025
Department of Orthopedics, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, People's Republic of China.
Objective: The incidence of anterior cruciate ligament (ACL) ruptures has been increasing annually. However, clinical surgeons have overlooked the impaction fractures of the posterolateral tibial plateau and lateral femoral condyle in patients with ACL ruptures. The purpose of the present study was to report the detection rate of the posterolateral tibial plateau impaction fractures in patients with ACL ruptures, and to evaluate the functional outcomes of patients following ACL reconstruction (ACLR) without treatment of the tibial fractures at a 2-year postoperative follow-up.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!