Valve Frame Geometry and Arrhythmia Risk Following Self-Expanding Transcatheter Pulmonary Valve Replacement.

Pediatr Cardiol

School of Medicine, Children's Hospital Colorado, The Heart Institute, University of Colorado Denver|Anschutz Medical Campus, 13123 E 16Th Ave, Box 100, Aurora, CO, 80045-2560, USA.

Published: January 2025

Though major complications during transcutaneous pulmonary valve replacement (TPVR) are rare, clinically-significant ventricular arrythmia (CSVA) has been reported following self-expanding valve placement. We assess whether alterations in valve frame dimensions and geometry within the right ventricular outflow tract (RVOT) post-implantation in patients who underwent TPVR with Harmony TPV25 or Alterra contribute to CSVA risk. A single center review was performed of patients who underwent TPVR with either Harmony TPV25 or Alterra Pre-stent between August 2019 and April 2023. Using post-procedural 3D rotational acquisitions, minimum and maximum diameters were measured at 5 locations along the valve frame and perimeter and cross-sectional area (CSA) were measured closest to the pulmonary artery bifurcation and right ventricular (RV) cavity. To assess the relationship between the RVOT and valve frame, a RVOT-to-valve frame ratio together with percentage expansion, circularity and expansion ratios, and eccentricity indices were calculated. Twenty-eight patients were included (14 Harmony TPV25, 14 Alterra pre-stent). CSVA was seen more often in patients with congenital pulmonary stenosis (p = 0.02). CSVA was associated with a larger mean valve frame perimeter (118.3 vs 108.6 mm, p = 0.03) and CSA (1124.5 vs 926.2mm, p = 0.03) closest to the RV cavity. No associations between difference in diameters, RVOT-to-valve frame ratio, parameters evaluating valve frame geometry, and level of implant and CSVA were demonstrated. No single mechanism was identified that contributed to CSVA in patients following self-expanding valve implantation. Future studies implementing these mathematical constructs and measurements to a larger cohort of self-expanding valve patients may yield more instructive results.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00246-024-03767-4DOI Listing

Publication Analysis

Top Keywords

valve frame
24
self-expanding valve
12
harmony tpv25
12
tpv25 alterra
12
valve
11
frame geometry
8
pulmonary valve
8
valve replacement
8
patients underwent
8
underwent tpvr
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!