Quality by Design-Steered Chromatographic Separation and Identification of the Geometric Isomers of Capsiate by Reversed-Phase HPLC and LC-MS.

J Chromatogr Sci

Nutrition and Bromatology Group, Department of Analytical Chemistry and Food Science, Faculty of Science, Universidade de Vigo, E-32004 Ourense, Spain.

Published: January 2025

An efficient reverse-phase high-performance liquid chromatographic method, based on the design of the experiment approach, was developed for the simultaneous determination of capsiate isomers. Critical method parameters, i.e., flow rate and mobile phase composition, demarcated during preliminary screening were optimized using central composite design. Chromatographic separation was achieved on a Nucleodur C18 column (250 × 4.6 mm, 5 μm), with the mobile phase consisting of water-acetonitrile (40:60), both acidified with 0.1% v/v formic acid, passed at a flow rate of 1 mL/min. E- and Z-capsiates were eluted from the column at the retention times of 18.56 ± 0.09 and 17.30 ± 0.08 min, respectively, with a resolution factor of 1.693 ± 0.046. The method was found to be linear within the concentration range of 1.054-5.270 and 8.623-43.115 μg/mL for Z- and E-isomers, respectively, with an R2 of >0.99. Recovery of the individual values was in range of 96.15-101.92%, with a relative standard deviation of <2%. The developed method was used to quantify capsiate isomers extracted from sweet pepper fruits. Therefore, the proposed method is presented for optimum isomeric resolution of these closely related E- and Z-isomers with convenient sample preparation, acceptable run-time, cost effectiveness and use of conventional instruments.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmaf001DOI Listing

Publication Analysis

Top Keywords

chromatographic separation
8
flow rate
8
mobile phase
8
quality design-steered
4
design-steered chromatographic
4
separation identification
4
identification geometric
4
geometric isomers
4
isomers capsiate
4
capsiate reversed-phase
4

Similar Publications

Cell-to-cell heterogeneity in lipid signaling underlies variations in response and recurrence for many cancers, including leukemias. A highly parallel, miniaturized thin-layer chromatographic platform capable of assaying single cells was developed. Ultrasmall volumes (50 pL) of standard fluorescent lipids were separated with excellent repeatability, reproducibility, and limits of detection.

View Article and Find Full Text PDF

Background: Selpercatinib, a selective RET kinase inhibitor, is approved for treating various cancers with RET gene mutations such as RET-rearranged thyroid cancer and non-small cell lung cancer. The presence of process-related and degradation impurities in its active pharmaceutical ingredient (API) can significantly affect its safety and effectiveness. However, research on detecting these impurities is limited.

View Article and Find Full Text PDF

The intricate morphology, physicochemical properties, and interacting proteins of lipid droplets (LDs) are associated with cell metabolism and related diseases. To uncover these layers of information, a solvatochromic and photosensitized LDs-targeted probe based on the furan-based D-D-π-A scaffold is developed to offer the following integrated functions. First, the turn-on fluorescence of the probe upon selectively binding to LDs allows for direct visualization of their location and morphology.

View Article and Find Full Text PDF

Sequential separation of anti-diabetic drugs in the presence of melamine as impurity using chromatographic methods.

BMC Chem

January 2025

Pharmaceutical Chemistry Department, Faculty of Pharmacy, Nahda University, Sharq El-Nile, Beni-Suef, 62511, Egypt.

The study of green analytical chemistry has garnered significant attention in the context of mitigating global environmental contamination. In this study, we present two methodologies for environmentally friendly chromatography that enable simultaneous and specific determination of Saxagliptin (SAX), metformin (MET), and a pharmacopoeial impurity of MET known as melamine (MEL). The initial method employed in this study is High-Performance Thin Layer Chromatography (HPTLC), which utilized 60 F 254 silica gel-coated Mark HPTLC plates on aluminum sheets as the stationary phase.

View Article and Find Full Text PDF

A non-derivatized high-performance liquid chromatographic (HPLC) method was developed for the simultaneous quantification of hydroxyl acids and their amination products in ammonolysis reaction mixtures. By optimizing the mobile phase composition and pH (0.04 M KHPO-5% methanol, pH = 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!