. Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation.. Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model. The sensitive volume of the detector used in measurements was also considered. If the measurements and simulations show good agreement, the dose distribution and absolute dose delivered by SFB can be accurately estimated. Three types of dose distributions were delivered to human salivary gland cells (HSGc-C5): uniform dose distribution (UDD), and one-dimensional (1D) grid-like dose distributions (GDD) with 6 mm and 8 mm spacing. These provided high (Peak-to-Valley Dose Ratio, PVDR = 4.0) and low (PVDR = 1.64) dose differences between peak and valley doses, respectively. Linear-Quadratic (LQ) model parameters for HSGc-C5 were derived from the UDD and cell survival fractions (SF) were simulated for 1D GDD using these values.. Good agreement was observed between measurements and simulations when accounting for detector volume. However, the TPS results overestimated dose in steep gradient region, likely due to the 2.0 mm calculation resolution. LQ parameters for HSGc-C5 were= 0.34 and= 0.057. The 1D GDD with 6 mm spacing showed good agreement between simulations and experiments, but the 8.0 mm spacing resulted in lower experimental cell survival.. We successfully simulated the GDD and conducted SF simulations. The results suggest potential cell-killing effects due to high-dose differences in SFB.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ada964DOI Listing

Publication Analysis

Top Keywords

dose distributions
16
dose
12
carbon ion
12
spatially fractionated
12
cell survival
12
good agreement
12
delivered dose
8
ion beams
8
sfb accurately
8
measurements simulations
8

Similar Publications

Chlorogenic acid (CGA) is a polyphenolic compound widely distributed in the diet. It has been shown to have a variety of potential health benefits and is also administered as a food supplement. However, the report on its safety assessment is sparse.

View Article and Find Full Text PDF

Despite the high frequency of pregnancies complicated by abnormal glucose metabolism associated with obesity, methylmercury (MeHg) metabolism in pregnant women with abnormal glucose metabolism is unclear. We aimed to elucidate the MeHg tissue distribution in obese female mice with abnormal glucose metabolism and their fetuses. Female C57BL/6J mice were fed a high-fat diet (HFD) or a standard diet (Ctrl) for 12 weeks and mated.

View Article and Find Full Text PDF

Purpose: Long-axial field-of-view PET scanners capture multi-organ tracer distribution with high sensitivity, enabling lower dose dynamic protocols and dual-tracer imaging for comprehensive disease characterization. However, reducing dose may compromise data quality and time-activity curve (TAC) fitting, leading to higher bias in kinetic parameters. Parametric imaging poses further challenges due to noise amplification in voxel-based modelling.

View Article and Find Full Text PDF

Background: Surveys conducted between 2015 and 2022 showed growing concern among European eye care practitioners about myopia management, though adoption of effective strategies varied. This study updates findings from 2024, analysing trends in attitudes and strategies for myopia management across Europe from 2015 to 2024.

Methods: A cross-sectional online survey targeting European eye care practitioners was distributed in multiple languages through professional bodies.

View Article and Find Full Text PDF

Direct-to-treatment adaptive radiotherapy: live planning of spine metastases using novel CBCT.

Int J Radiat Oncol Biol Phys

March 2025

Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Halifax, Canada; Department of Radiation Oncology, Dalhousie University, Halifax, Canada; Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada.

Purpose: CBCT-based online adaptive radiation therapy is carried out using a synthetic CT, sCT, created through deformable registration between the patient-specific fan-beam CT, FBCT, and daily CBCT. Ethos 2.0 allows for plan calculation directly on HyperSight CBCT and uses AI-informed tools for daily contouring without the use of a priori information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!