Background And Objective: Patients with thoracic aortic aneurysm and dissection (TAAD) are often asymptomatic but present acutely with life threatening complications that necessitate emergency intervention. Aortic diameter measurement using computed tomography (CT) is considered the gold standard for diagnosis, surgical planning, and monitoring. However, manual measurement can create challenges in clinical workflows due to its time-consuming, labour-intensive nature and susceptibility to human error. With advancements in artificial intelligence (AI), several models have emerged in recent years for automated aortic diameter measurement. This article aims to review the performance and clinical relevance of these models in relation to clinical workflows.
Methods: We performed literature searches in PubMed, Scopus, and Web of Science to identify relevant studies published between 2014 and 2024, with the focus on AI and deep learning aortic diameter measurements in screening and diagnosis of TAAD.
Key Content And Findings: Twenty-four studies were retrieved in the past ten years, highlighting a significant knowledge gap in the field of translational medicine. The discussion included an overview of AI-powered models for aortic diameter measurement, as well as current clinical guidelines and workflows.
Conclusions: This article provides a thorough overview of AI and deep learning models designed for automatic aortic diameter measurement in the screening and diagnosis of thoracic aortic aneurysms (TAAs). We emphasize not only the performance of these technologies but also their clinical significance in enabling timely interventions for high-risk patients. Looking ahead, we envision a future where AI and deep learning-powered automatic aortic diameter measurement models will streamline TAAD clinical management.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11729799 | PMC |
http://dx.doi.org/10.21037/atm-24-171 | DOI Listing |
Ann Transl Med
December 2024
Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Hong Kong, China.
Background And Objective: Patients with thoracic aortic aneurysm and dissection (TAAD) are often asymptomatic but present acutely with life threatening complications that necessitate emergency intervention. Aortic diameter measurement using computed tomography (CT) is considered the gold standard for diagnosis, surgical planning, and monitoring. However, manual measurement can create challenges in clinical workflows due to its time-consuming, labour-intensive nature and susceptibility to human error.
View Article and Find Full Text PDFJ Endovasc Ther
January 2025
Aortic Center, Hôpital Marie-Lannelongue, Groupe Hospitalier Paris Saint Joseph, Université Paris-Saclay, INSERM UMR_S 999, Le Plessis Robinson, France.
Introduction: Management of patients with large aortic arch aneurysms who are considered high risk for frozen elephant trunk technique have been challenging, especially when they have a dilated ascending aorta (AA) that precludes total endovascular branched repair (arch BEVAR). A viable option in our armamentarium is wrapping of the AA (AW), and zone 0 Ishimaru TEVAR.
Methods: Retrospective analysis of our aortic database from 2013 to 2024 to select high-risk patients with aortic arch aneurysm that had an AW and TEVAR.
JVS Vasc Sci
December 2024
Department of Cardiovascular Science, Lewis Katz School of Medicine at Temple University, Philadelphia, PA.
Treatment with an inhibitor of glucose use via glucose transporters (GLUT) has been shown to attenuate experimental abdominal aortic aneurysm (AAA) development in mice. Vascular smooth muscle cell (VSMC) signaling seems to be essential for angiotensin II (Ang II)-induced AAA in mice. Accordingly, we have tested a hypothesis that VSMC silencing of the major GLUT, GLUT1, prevents AAA development and rupture in mice treated with Ang II plus β-aminopropionitrile.
View Article and Find Full Text PDFZhonghua Xin Xue Guan Bing Za Zhi
January 2025
Cardiology Department, Second Affiliated Hospital of Dalian Medical University, Dalian116021, China.
To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.
View Article and Find Full Text PDFClin Endocrinol (Oxf)
January 2025
Oxford Heart Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
Objective: The risk of aortic dissection is increased in Turner Syndrome (TS). Aortic dilation is thought to contribute to this risk and may be managed with elective aortic surgery. New TS guidance has lowered the aortic size thresholds for consideration of aortic surgery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!