Naloxone can effectively rescue victims from opioid overdose, but less than 5% survive due to delayed or absent first responder intervention. Current overdose reversal systems face key limitations, including low user adherence, false positive detection, and slow antidote delivery. Here, we describe a subcutaneously implanted robotic first responder to overcome these challenges. This implantable system for opioid safety continuously monitors vital signs, detecting opioid overdose through an algorithm analyzing the interplay of cardiorespiratory responses. To address battery concerns with continuous monitoring and multi-sensing modality, an adaptive algorithm dynamically adjusts sensor resolution, reducing the need for frequent charging. Furthermore, the implant includes an ultra-rapid naloxone delivery pump, delivering the 10-mg antidote within 10 s. In animal trials, the robotic first responder successfully revived 96% of overdosed pigs ( = 25) within 3.2 min, showcasing its potential to dramatically improve survival rates and combat the opioid epidemic.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11735030PMC
http://dx.doi.org/10.1016/j.device.2024.100517DOI Listing

Publication Analysis

Top Keywords

implantable system
8
system opioid
8
opioid safety
8
opioid overdose
8
robotic responder
8
opioid
5
safety naloxone
4
naloxone effectively
4
effectively rescue
4
rescue victims
4

Similar Publications

Background: The ultimate goal of arthroplasty is thought to be the ability to "forget" a joint implant in daily activities. The Forgotten Joint Score (FJS-12), a score system that evaluates how much patients have been able to forget their hip or knee prosthesis, was recently published. It is based on a self-administered questionnaire that consists of 12 items.

View Article and Find Full Text PDF

Introduction: The role of the sympathetic nervous system in the initiation and continuation of ventricular tachyarrhythmias (VTA) is well established. However, whether CSD reduces implantable cardioverter-defibrillator (ICD) shocks and recurrent VTA is still uncertain.

Methods: A comprehensive literature search was performed at Medline and Embase until March 2023.

View Article and Find Full Text PDF

Totally implantable central venous catheters (CVCs) are widely used in the management of patients with malignant diseases. Conventionally, port implantations were carried out by general surgeons and vascular radiologists. In recent years, the medical staff of the Medical Oncology department at the Central University Hospital of Asturias (HUCA) has developed a simplified methodology for the routine implantation of these devices.

View Article and Find Full Text PDF

Creating durable, motion-compliant neural interfaces is crucial for accessing dynamic tissues under in vivo conditions and linking neural activity with behaviors. Utilizing the self-alignment of nano-fillers in a polymeric matrix under repetitive tension, here, we introduce conductive carbon nanotubes with high aspect ratios into semi-crystalline polyvinyl alcohol hydrogels, and create electrically anisotropic percolation pathways through cyclic stretching. The resulting anisotropic hydrogel fibers (diameter of 187 ± 13 µm) exhibit fatigue resistance (up to 20,000 cycles at 20% strain) with a stretchability of 64.

View Article and Find Full Text PDF

Jawline improvement using patient-specific angle implants with virtual planning in orthognathic surgery.

J Craniomaxillofac Surg

January 2025

Department of Oral and Maxillo-Facial Surgery, Head and Neck Institute, University Hospital Center of Nice, 31 avenue de Valombrose, 06100, Nice, France; Nice Côte d'Azur Clinical Research Unit (UR2CA), France. Electronic address:

There has been a recent increase in the global demand for jawline augmentation. Managing angle definition in patients undergoing orthognathic surgery remains challenging owing to the characteristics of classic mandibular osteotomy, which mostly allows sagittal mandibular movements but cannot modify the ramus height. The advent of computer-assisted surgical planning and computer-aided design/computer-aided manufacturing techniques for patient-specific implant fabrication has introduced new methods for jawline management.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!