Accurate 3D characterization of osteocyte lacunae is important when investigating the role of osteocytes under various physiological and pathological conditions but remains a challenge. With the continued development of laboratory X-ray micro-computed tomography, an increasing number of studies employ these techniques beyond traditional bone morphometry to quantify osteocyte lacunae. However, there is a lack of knowledge on the effect of measurement parameters on the image quality and resolution and in turn the osteocyte lacunae quantification. Herein, we have examined the interplay between scan parameters and the resultant lacunar quantification in terms of lacunar size, shape, and density by comparison with a synchrotron benchmark dataset. We summarize our conclusions in a guide for use of μ-CT for osteocyte lacunar quantification: (1) Identification of the measurement requirements to address the research questions. (2) Collection and preparation of suitable sample(s) that fulfills these requirements. (3) Experimental considerations including determination of the required voxel size, in turn dictating the maximum FOV and by extension the maximum size of the sample(s). The experimental parameters chosen should ensure optimal image contrast, sufficient signal to noise, angular sampling etc. Usually, it is advisable to measure as well as possible within the limits of time, budget, data storage and analysis capabilities. (4) Data analysis and reporting of the results, including visual examination of the data at multiple steps in the analysis, to ensure correct feature identification and suitable reporting approaches. (5) Cross study comparisons, which may be unsuitable if the experimental conditions and analysis strategies are not comparable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bone.2025.117391DOI Listing

Publication Analysis

Top Keywords

osteocyte lacunae
12
measurement parameters
8
osteocyte lacunar
8
laboratory x-ray
8
x-ray micro-computed
8
micro-computed tomography
8
lacunar quantification
8
osteocyte
5
systematic study
4
study measurement
4

Similar Publications

Accurate 3D characterization of osteocyte lacunae is important when investigating the role of osteocytes under various physiological and pathological conditions but remains a challenge. With the continued development of laboratory X-ray micro-computed tomography, an increasing number of studies employ these techniques beyond traditional bone morphometry to quantify osteocyte lacunae. However, there is a lack of knowledge on the effect of measurement parameters on the image quality and resolution and in turn the osteocyte lacunae quantification.

View Article and Find Full Text PDF

Bone tissue is a biological composite material with a complex hierarchical structure that could continuously adjust its internal structure to adapt to the alterations in the external load environment. The fluid flow within bone is the main route of osteocyte metabolism, and the pore pressure as well as the fluid shear stress generated by it are important mechanical stimuli perceived by osteocytes. Owing to the irregular multiscale structure of bone tissue, the fluid stimulation that lacunar-canalicular network (LCN) in different regions of the tissue underwent remained unclear.

View Article and Find Full Text PDF

Objective: To elucidate the mechanisms underlying diabetic osteoporosis, we conducted a comprehensive histological examination of the femora of Spontaneously Diabetic Torii-Lepr (SDT-fa/fa) rats, an established model of obesity-related type 2 diabetes.

Materials And Methods: Femora from 12 30-week-old male SDT-fa/fa rats and age-matched Sprague-Dawley (SD) rats (controls) were used for detailed histochemical analyses, including tartrate-resistant acid phosphatase (TRAP), cathepsin K, alkaline phosphatase (ALP), phosphoethanolamine/ phosphocholine phosphatase 1 (PHOSPHO1), dentin matrix protein (DMP)-1, matrix extracellular phosphoglycoprotein (MEPE), sclerostin, osteocalcin staining, silver impregnation, von Kossa staining, and micro-computed tomography (CT).

Results: Micro-CT and hematoxylin-eosin staining demonstrated significantly reduced trabecular bone volume in the femoral metaphyses of SDT-fa/fa rats.

View Article and Find Full Text PDF

Histomorphometry is an important technique in the evaluation of non-traumatic osteonecrosis of the femoral head (ONFH). Quantification of empty lacunae and pyknotic cells on histological images is the most reliable measure of ONFH pathology, yet it is time and manpower consuming. This study focused on the application of artificial intelligence (AI) technology to tissue image evaluation.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on the osteochondral interface, which includes calcified cartilage (CC) and subchondral bone (SCB), and presents a new method for analyzing chondrocyte and osteocyte lacunae in human knee samples using advanced imaging techniques.
  • Researchers employed a combination of a marker-controlled watershed algorithm and deep learning (specifically nnU-Net) to enhance the 3D segmentation of cell lacunae, effectively improving the assessment of their structures.
  • Findings showed that while chondrocyte characteristics didn't differ significantly between control and osteoarthritic knees, osteocytes in the osteoarthritic group exhibited lower anisotropy and tended to be more spherical,
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!