Low noise and high repetition rate optical frequency combs are desirable for many applications, from timekeeping to precision spectroscopy. For example, gigahertz repetition rate sources greatly increase the acquisition speed of spectra in a dual-comb modality when compared to lower repetition rate sources, while still maintaining sufficient instantaneous resolution to resolve ro-vibrational signatures from molecules in a variety of conditions. In this paper, we present the stabilization and characterization of a turnkey commercial 1 GHz mode-locked laser that operates at telecom wavelengths (1.56 μm). Fiber amplification and spectral broadening result in high signal-to-noise ratio detection and stabilization of with 438 mrad of residual phase noise (integrated from 10 to 10 Hz). Simultaneously, we stabilize the beatnote between the nearest comb mode and a cavity stabilized continuous-wave laser at 1.55 μm with 41 mrad of residual phase noise (integrated from 10 to 10 Hz). This robust, self-referenced comb system is built with off-the-shelf polarization-maintaining fiber components and will be useful for a wide range of low noise frequency comb applications that benefit from the increased repetition rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11729768PMC
http://dx.doi.org/10.1364/osac.396597DOI Listing

Publication Analysis

Top Keywords

repetition rate
16
frequency comb
8
156 μm
8
low noise
8
rate sources
8
mrad residual
8
residual phase
8
phase noise
8
noise integrated
8
fully phase-stabilized
4

Similar Publications

Background: Concurrent exercise (CE), an emerging exercise modality characterized by sequential bouts of aerobic (AE) and resistance exercise (RE), has demonstrated acute benefits on executive functions (EFs) and neuroelectric P3 amplitude. However, the effect of acute CE on inhibitory control, a sub-component of EFs, and P3 amplitude remains inconclusive. Moreover, exploring the mechanisms underlying the effects of acute exercise on EFs contributes to scientific comprehension, with lactate recognized as a crucial candidate positively correlated with EFs.

View Article and Find Full Text PDF

Some technical limitations to using the eccentric mode to measure peak eccentric strength of the hamstrings (PTH) were raised. PTH also has limited validity to predict performance or injury risk factor. Therefore, our aim was to compare PTH and other isokinetic variables tested in the eccentric and passive modes.

View Article and Find Full Text PDF

Aims: We aimed to establish one-minute sit-to-stand test (1-min STST) cut-off values that align with the guideline-recommended six-minute walk test (6MWT) thresholds (165m and 440m) for one-year mortality risk stratification in pulmonary hypertension (PH) patients. Furthermore, we aimed to compare clinical characteristics and long-term mortality among patients stratified by these proposed 1-min STST cut-offs.

Methods: All patients performed the 1-min STST and 6MWT.

View Article and Find Full Text PDF

Laser-plasma acceleration of protons offers a compact, ultra-fast alternative to conventional acceleration techniques, and is being widely pursued for potential applications in medicine, industry and fundamental science. Creating a stable, collimated beam of protons at high repetition rates presents a key challenge. Here, we demonstrate the generation of multi-MeV proton beams from a fast-replenishing ambient-temperature liquid sheet.

View Article and Find Full Text PDF

This study analyzed the acute and time-course changes following one resistance training (RT) set (1SET) and three sets (3SET) on hemodynamic and physical performance parameters in individuals with different cognitive impairment levels. Thirty-nine individuals (22 women and 17 men aged 80 ± 9 years) grouped by cognitive impairment (mild [MILD], moderate [MOD], and severe [SEV]) randomly performed two protocols, each separated by one week, of 1SET or 3SET of 10 repetitions. Before (PRE), immediately (POST), and 72 h after (POST72) protocols, the participants performed the following measurements: systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), 1-kg medicine ball throw (MBT) distance, five-repetition sit-to-stand (STS) time, and handgrip strength (HGS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!