Stanford type B aortic dissection involving the left subclavian artery (LSA) poses significant clinical challenges. The Castor single-branch stent graft and in situ fenestration are commonly used techniques, but the better endovascular treatment remains debated. This study evaluates the clinical effects of the Castor single-branched stent graft versus in situ fenestration in treating Stanford type B aortic dissection involving the LSA. We selected 75 patients with Stanford type B aortic dissection involving the LSA, admitted to the Second Affiliated Hospital of Nanchang University from January 2018 to May 2022. All patients underwent thoracic endovascular aortic repair; 34 received the Castor single-branched stent graft, while 41 underwent in situ fenestration. Clinical efficacy and perioperative complications were compared. The technical success rate of the Castor single-branch stent graft was significantly higher than that of in situ fenestration (97.06% vs 80.49%, P = .04). The Castor group exhibited significantly better outcomes in operative time (136.45 ± 25.53 min vs 157.08 ± 18.14 min), LSA blood flow recovery time (6.8 ± 2.3 min vs 20.1 ± 9.8 min), blood loss (29.03 ± 9.78 mL vs 35.69 ± 10.77 mL), contrast medium usage (288.71 ± 72.70 mL vs 352.78 ± 81.02 mL), and immediate postoperative endoleaks (1/34 vs 7/41) (P < .05). Stroke incidence (1/34 vs 2/41) and perioperative mortality (0/34 vs 1/41) were similar (P > .05). Hospital stays were comparable (15.71 ± 6.04 days vs 14.22 ± 5.01 days, P = .28). However, the cost of medical supplies (154,168.62 ± 28,288.44 CNY vs 119,589.72 ± 34,199.67 CNY) and total hospital expenses (192,665.88 ± 40,027.99 CNY vs 153,920.47 ± 42,670.87 CNY) were significantly higher in the Castor group (P < .05). The median follow-up time was 9 months (1-60 months). Follow-up showed similar 30-day postoperative mortality (1/41 vs 0/34, P = 1.00), stent patency (33/34 vs 39/41, P = .67), and stent migration rates (0/34 vs 1/41, P = 1.00). However, the endoleak rate was significantly higher in the in situ fenestration group (11/41 vs 1/34, P = .01). Both the Castor single-branch stent graft and the in situ fenestration technique effectively protect and reconstruct the LSA in Stanford type B aortic dissection, with the Castor single-branch stent graft showing higher technical success and fewer complications, indicating better clinical potential.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MD.0000000000040623DOI Listing

Publication Analysis

Top Keywords

stent graft
20
situ fenestration
20
stanford type
16
type aortic
16
aortic dissection
16
dissection involving
16
castor single-branched
12
single-branched stent
12
graft situ
8
fenestration treating
8

Similar Publications

Stanford type B aortic dissection involving the left subclavian artery (LSA) poses significant clinical challenges. The Castor single-branch stent graft and in situ fenestration are commonly used techniques, but the better endovascular treatment remains debated. This study evaluates the clinical effects of the Castor single-branched stent graft versus in situ fenestration in treating Stanford type B aortic dissection involving the LSA.

View Article and Find Full Text PDF

Ascending-to-Descending Aortic Bypass of a Thoracic Stent Graft Infection with a Rare Pathogen.

Surg Infect (Larchmt)

January 2025

Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan.

Stent graft infection (SGI) caused by complex is rare. The usage of ascending-to-descending aortic bypass (ADAB) in such situations has not yet been fully discussed. Case report and literature review.

View Article and Find Full Text PDF

Objective: Paravisceral aortic lesions present significant challenges for endovascular treatment. This retrospective analysis of consecutively treated patients from April 2017 to June 2021 aimed to analyse the outcome of primary intra-operative embolisation of aortic complicated pseudoaneurysms and gutter channels during parallel graft (PG) repair of paravisceral symptomatic aortic pseudoaneurysms.

Methods: Patients with symptomatic pseudoaneurysms of the paravisceral aorta treated with PGs using chimney or periscope configurations were included.