AI Article Synopsis

  • This study investigates the balance between avoiding platelet wastage and ensuring transfusion efficacy, focusing on the effects of platelet compatibility and product modification on reaction rates.
  • A review of over 21,000 platelet transfusions revealed a 1.33% reaction rate, with major incompatibility and irradiated products associated with increased odds of adverse reactions.
  • The findings suggest that both platelet compatibility and product modification independently impact transfusion reactions, informing future policies for selecting platelet products for patients.

Article Abstract

Background: Allocating incompatible platelet components to avoid product wastage must be balanced against the risk of reduced efficacy and adverse outcomes. The impact of platelet compatibility in association with product irradiation or pathogen reduction is unknown. This study aims to determine the combined and independent impact of platelet compatibility and component modification on transfusion reaction rate.

Study Design And Methods: A retrospective review of all adult platelet transfusions from 2020 to 2022 was performed, including all reported reactions. Logistic regression was performed to evaluate the significance of ABO compatibility and unit modification for reaction rate.

Results: Out of 21,330 transfusions to 3450 patients, 285 (1.33%) reactions were reported and 178 (0.83%) were diagnosed as related to transfusion, predominantly febrile nonhemolytic (n = 59) and allergic (n = 102). The compatibility of transfusion was 67.7% ABO identical, 13.8% ABO minor incompatible, 17.2% ABO major incompatible, and 1.4% ABO bidirectionally incompatible. Irradiated, unmodified, and pathogen-reduced single-donor platelets were transfused in 70.9%, 21.8%, and 7.3% of cases, respectively. Univariable regression demonstrated increased odds of reaction for major incompatibility vs. ABO identical (OR: 1.92; 95% CI: 1.36-2.71) and irradiated vs. unmodified (OR: 2.34; 95% CI: 1.45-3.91), which were confirmed by multivariable analysis. The effect of compatibility and unit modification were independent in all analyses.

Conclusions: The results demonstrate a trend of increasing reaction rate associated with major incompatibility and product irradiation. This study provides additional data to inform institutional policies guiding product selection for individual patients.

Download full-text PDF

Source
http://dx.doi.org/10.1111/trf.18130DOI Listing

Publication Analysis

Top Keywords

transfusion reaction
8
reaction rate
8
impact platelet
8
platelet compatibility
8
product irradiation
8
compatibility unit
8
unit modification
8
abo identical
8
irradiated unmodified
8
major incompatibility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!