To compare the impact of manual right arm blood pressure measurement with computer-controlled blood pressure meter (CCBPM) on the detection rate of hypertension among elderly individuals. This was a cross-sectional study. Elderly residents undergoing routine health check-up in a village in Jiangxi Province from April to June 2024 were enrolled. Manual blood pressure measurements were performed on the right arm using an electronic sphygmomanometer, while standardized dual-arm synchronized blood pressure assessments were conducted using the CCBPM. Blood pressure data were recorded from three sources: manual measurement on the right arm; the first CCBPM measurement on the arm with higher systolic blood pressure (CCBPM single); and the mean blood pressure of the arm with higher systolic blood pressure from two (if the difference between the first two measurements was less than 5 mmHg, 1 mmHg=0.133 kPa) or three (if the difference exceeded 5 mmHg) CCBPM measurements (CCBPM mean). Hypertension detection rates from these three datasets were compared. Subgroup analysis was performed according to age (60-74 years old as the elderly group,≥75 years old as the senior group) and gender. Intra-group correlation coefficient () was analyzed to evaluate the consistency of blood pressure data of different blood pressure measurement methods, and value was analyzed to evaluate the consistency of hypertension classification determined by different blood pressure measurement methods. A total of 1 498 participants were enrolled, aged (71.30±6.83) years old, including 678 males (45.26%). The blood pressure and heart rate measured by the artificial right arm blood pressure measurement were higher than those measured by CCBPM single (blood pressure: (140.09±17.19)/(82.40±10.93) mmHg vs. (135.31±18.98)/(81.23±10.51) mmHg; heart rate: (75.76±11.72) beats/min vs.(72.94±11.21) beats/min) and CCBPM mean (blood pressure: (140.09±17.19)/(82.40±10.93) mmHg vs. (134.64±18.39)/(80.28±9.78) mmHg; heart rate: (75.76±11.72) beats/min vs. (72.87±10.70) beats/min, all <0.05). The detection rate of hypertension determined by CCBPM mean was significantly lower than that of artificial right arm (40.25% (603/1 498) vs.54.34% (814/1 498)) and CCBPM single (40.25% (603/1 498) vs. 44.79% (671/1 498), all <0.05). Subgroup analysis showed that that the detection rate of hypertension determined by CCBPM mean was lower than that measured by artificial right arm regardless of gender and age (all <0.05). The consistency of blood pressure data between artificial right arm and the CCBPM mean was moderate (systolic blood pressure: =0.70; diastolic blood pressure: =0.62), with less consistent classification (=0.37). The consistency of blood pressure data between CCBPM single and CCBPM mean is extremely high (systolic blood pressure: =0.94; diastolic blood pressure: =0.91), with highly consistent classification (=0.74). Artificial right arm blood pressure measurement in physical examinations may overestimate the hypertension detection rate, and the standardized dual-arm synchronized blood pressure measurement using CCBPM can reduce irregular blood pressure measurement.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn112148-20240725-00416DOI Listing

Publication Analysis

Top Keywords

blood pressure
64
pressure measurement
20
blood
16
pressure
16
arm blood
12
heart rate
12
artificial arm
8
hypertension elderly
8
ccbpm
8
ccbpm blood
8

Similar Publications

Blood Flow Restricted Resistance Exercise in Well-Trained Men: Salivary Biomarker Responses and Oxygen Saturation Kinetics.

J Strength Cond Res

December 2024

Jayhawk Athletic Performance Laboratory, Wu Tsai Human Performance Alliance, University of Kansas, Lawrence, Kansas.

Eserhaut, DA, DeLeo, JM, and Fry, AC. Blood flow restricted resistance exercise in well-trained men: Salivary biomarker responses and oxygen saturation kinetics. J Strength Cond Res 38(12): e716-e726, 2024-Resistance exercise with continuous lower-limb blood flow restriction (BFR) may provide supplementary benefit to highly resistance-trained men.

View Article and Find Full Text PDF

Prehospital Interventions to Reduce Discomfort From Spinal Immobilization in Adult Trauma Patients: A Scoping Review.

J Trauma Nurs

January 2025

Author Affiliations: Department of Community Medicine, Information and Health Decision Sciences, University of Porto, Porto, Portugal (Dr Mota); Health School, Polytechnic Institute of Viseu, Viseu, Portugal (Drs Mota, Santos, and Cunha); Health Sciences Research Unit: Nursing (UICISA: E), Coimbra, Portugal (Drs Mota and Cunha); CINTESIS@RISE - Center for Health Technology and Services Research, University of Porto, Porto, Portugal (Drs Mota and Santos); Academic Clinical Centre of Beiras, Covilhã, Portugal (Drs Mota and Cunha); Abel Salazar Institute of Biomedical Sciences, University of Porto, Porto, Portugal (Drs Melo and Santos); Portugal Centre for Evidence-Based Practice: A Joanna Briggs Institute Centre of Excellence, Coimbra, Portugal (Dr Santos); Hospital São Teotónio, Tondela Viseu Hospital Centre, Viseu, Portugal (Dr Abrantes); Santa Casa da Misericórdia de Seia, Seia, Portugal (Dr Monteiro); and Nursing School of Porto, Porto, Portugal (Dr Santos).

Background: Spinal immobilization, a widely used trauma prehospital intervention, is known to cause discomfort, yet little is known about interventions to reduce this discomfort.

Objective: This scoping review aims to evaluate prehospital interventions to reduce discomfort from spinal immobilization in adult trauma patients.

Method: This scoping review assessed prehospital pharmacological and nonpharmacological interventions to address discomfort from spinal immobilization in adult trauma patients.

View Article and Find Full Text PDF

A scoping review protocol on brain PaCO2 levels at altitude.

PLoS One

January 2025

Division of Neurology, Department of Medicine, The Ottawa Hospital, Ottawa, Ontario, Canada.

Background: Aeromedical transfer of patients with ischemic stroke to access hyperacute stroke treatment is becoming increasingly common. Little is known about how rapid changes of altitude and atmospheric pressure can impact cerebral perfusion and ischemic burden. In patients with ischemic stroke, there is a theoretical possibility that this physiologic response of hypoxia-driven hyperventilation at higher altitude can lead to a relative drop in PaCO2.

View Article and Find Full Text PDF

The objective of this review is to evaluate and summarize the evidence base for the effects of monetary intervention approaches (the use of positive monetary reinforcers and gains) on diabetes outcomes. A reproducible search using OVID Medline, PubMed, Scopus, and CINAHL was conducted. Articles published from database creation up to July 2024 were searched.

View Article and Find Full Text PDF

Background: Increasing life expectancy has led to a rise in nursing home admissions, a context in which older adults often experience chronic physical and mental health conditions, chronic pain, and reduced well-being. Nonpharmacological approaches are especially important for managing older adults' chronic pain, mental health conditions (such as anxiety and depression), and overall well-being, including sensory stimulation (SS) and therapist support (TS). However, the combined effects of SS and TS have not been investigated.

View Article and Find Full Text PDF