BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD. Between respective prepared abutments, 31 coordinates were identified and measured based on angles (line/point) and surfaces (curved/flat). Sixty impressions (dual stage 2-step putty reline technique) were divided into 5 groups (n=12/group): group PP (pre-preparation putty), group GP (gouging putty), group PS (polythene spacer), group CT (conventional temporary), and group MT (modified temporary), depending on spacer acquisition method. Coordinates measurements were conducted using a measuring microscope. Descriptive and inferential statistical tests (ANOVA, post hoc Tukey) determined between-group and within-group differences, at P≤0.05 significance level. RESULTS In short-span FPD, compared with control, the number of significantly different coordinates group-wise were GP (4 coordinates), PP (2 coordinates), and PS, CT, and MT (1 each). In long-span FPD, compared with control, the number of significantly different coordinates group-wise were group GP (12 coordinates), group PP (10 coordinates), group PS (5 coordinates), and group CT and group MT (4 each). CONCLUSIONS Different spacer acquisition methods produce varied thickness of spacers for relining of putty. CT and MT, when used as spacers, provided maximum accurate coordinates for angles (line/point) and surfaces (curved/flat).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11742236 | PMC |
http://dx.doi.org/10.12659/MSM.946537 | DOI Listing |
Med Sci Monit
January 2025
Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.
View Article and Find Full Text PDFFront Dent
May 2024
Department of Biostatistics and Epidemiology, School of Health, Bushehr University of Medical Sciences, Bushehr, Iran.
Some small defects may remain in the impression after making a two-step putty-light body impression. The aim of this study was to evaluate and compare the dimensional accuracy of 2-step and relined 2-step (3-step) putty-light body impressions. In this in vitro study, 30 impressions were made with putty, light body, and extra-light body addition silicone materials using the 2-step and 3-step impression techniques (N=15).
View Article and Find Full Text PDFBeijing Da Xue Xue Bao Yi Xue Ban
April 2020
Department of Prosthodontics, Center for Digital Dentistry, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Objective: To measure the dimensional data of complete dentures and to design a novel tray for recording maxillomandibular relationship of edentulous patients.
Methods: For the measurement, 100 pairs of complete dentures from the clinic were surveyed for the following parameters: a1, the distance between the middle fossa of the upper left and right first molars; a2, the anterior-posterior distance between the middle fossa of the upper first molars and the incisal edge; a3, the width of the upper denture; a4, the anterior-posterior length of the upper denture; a5, the height from the mesio-lingual cusp of the right upper first molar to the saddle surface; a5, the height from the central fossa of the right lower first molar to the saddle surface; a6, the height from the notch of the upper lip frenulum to the upper central incisor edge; a7, the least thickness of the labial saddle base in the upper central incisor region. Based on the data, the trays with different sizes were designed and fabricated, and the key parameters were: b1, the distance between the foramina of screw posts, b2, the anterior-posterior distance between the foramina of the screw posts and the incisal edge; b3, the width of the tray; b4, the anterior-posterior length of the tray; b5, the height of the posterior platform with the screw nut; b5, the height of the screw post; b6, the height of the anterior tray handle; b7, the thickness of the anterior tray handle.
Int J Oral Maxillofac Surg
September 2018
Department of Oral and Maxillofacial Surgery and Special Dental Care, University Medical Center Utrecht, Utrecht, The Netherlands.
Partial or complete resection of the maxilla during tumour surgery causes oronasal defects, leading to oral-maxillofacial dysfunction, for which the surgical obturator (SO) is an important treatment option. Traditional manufacturing of SOs is complex, time-consuming, and often results in inadequate fit and function. This technical note describes a novel digital workflow to design and manufacture a three-dimensional (3D)-printed hollow SO.
View Article and Find Full Text PDFInt J Dent
December 2016
College Of Dentistry, King Khalid University, Abha, Saudi Arabia.
The accurate duplicate cast obtained from a single impression reduces the profession clinical time, patient inconvenience, and extra material cost. The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with five mm spacer and two mm spacer.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!