Purpose: The aim of this study was to propose a simplified segmental scleral buckling (SSSB) technique that does not require break localization for less-experienced vitreoretinal surgeons.

Materials And Methods: This retrospective study compared the clinical results of 46 conventional and 23 SSSB (conventional segmental SB [CSSB] and SSSB, respectively) procedures in a tertiary referral retinal center in Taiwan between 2008 and 2019. In the CSSB group, breaks were localized during surgery. In the SSSB group, a wider sponge band and a longer scleral buckle were used to maximize the chances of sealing the retinal breaks based on the preoperative fundus examination findings and to minimize the positioning error caused by cyclotorsion, without performing indirect ophthalmoscopy. The primary outcome was assessed after 6 months. Patient characteristics, surgical parameters, and outcomes were compared between groups. The main outcomes were the duration of surgery, changes in visual acuity, primary success rate, rhegmatogenous retinal detachment recurrence rate, and the frequency of further laser photocoagulation.

Results: SSSB had a shorter duration than CSSB and was associated with more frequent use of longer and wider explants and need for further laser retinopexy. Both groups showed high primary success rates (95.65%).

Conclusion: The primary success rates for the SSSB and CSSB groups were comparable and equally high. SSSB required laser retinopexy more frequently and was a shorter procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11717345PMC
http://dx.doi.org/10.4103/tjo.TJO-D-23-00093DOI Listing

Publication Analysis

Top Keywords

segmental scleral
12
scleral buckling
12
primary success
12
simplified segmental
8
conventional segmental
8
laser retinopexy
8
success rates
8
sssb
7
scleral
4
buckling localization
4

Similar Publications

Purpose: The aim of this study was to propose a simplified segmental scleral buckling (SSSB) technique that does not require break localization for less-experienced vitreoretinal surgeons.

Materials And Methods: This retrospective study compared the clinical results of 46 conventional and 23 SSSB (conventional segmental SB [CSSB] and SSSB, respectively) procedures in a tertiary referral retinal center in Taiwan between 2008 and 2019. In the CSSB group, breaks were localized during surgery.

View Article and Find Full Text PDF

Purpose: To investigate changes in fluid reservoir turbidity parameters over time and its influence on visual performance in eyes with ocular surface disorders (OSD) wearing scleral contact lenses (SL).

Methods: Thirteen eyes with OSD were assessed for corrected distance visual acuity, contrast sensitivity (CS) and fluid reservoir turbidity using anterior segment optical coherence tomography at baseline, after 5 min and 0.5, 1, 2, 3 and 4 h of SL wear on day 1 and after 1 month.

View Article and Find Full Text PDF

Pulsed Ultrasound-Mediated Drug Delivery Enhancement Through Human Sclera.

Transl Vis Sci Technol

January 2025

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Purpose: The purpose of this study was to characterize whether pulsed ultrasound (PUS) affects transscleral drug delivery.

Methods: Fluorescein sodium (NaF, 376 Da) and fluorescein isothiocyanate-conjugated dextran 40 (FD-40, 40 kDa) were used as model drugs. Human sclera grafts were placed in modified Franz diffusion cells and were treated by PUS (1 megahertz [MHz], 0.

View Article and Find Full Text PDF

Purpose: To evaluate an alternative surgical approach for Port Delivery System with ranibizumab (PDS) implant and a novel application of Iridex laser system in Gottingen minipig model.

Methods: A total of seventeen male minipigs (Part 1: 9 animals in non-recovery and Part 2: 8 animals observed for 8-days post-surgery Part 2) received PDS implant insertion into each eye. The effect of Iridex 810 nm infrared diode laser with varying energy (power or duration) on transscleral pars plana ablation, surrounding ocular tissue and postsurgical vitreous hemorrhage (VH) was investigated.

View Article and Find Full Text PDF

Size Matters: A Comparative Study on Midday Fogging and Lens Settling in Patients With Keratoconus Wearing Mini-Scleral Lenses With Two Different Diameters.

Eye Contact Lens

November 2024

Department of Ophthalmology (E.B.V.), Kocaeli Kandıra M. Kazım Dinç State Hospital, Kocaeli, Turkey; Department of Ophthalmology (S.A.T.), Marmara University Medical School, Istanbul, Turkey; and Department of Ophthalmology and Visual Sciences (A.E.T.), West Virginia University Eye Institute, Morgantown, WV.

Purpose: The objective of this study was to compare the changes in postlens fluid optical density, timing and quantity of lens settling, and the clinical performance between two different mini-scleral lenses.

Methods: Seventeen eyes of 10 patients with keratoconus were fitted with a 15-mm mini-scleral lens (AirKone Scleral Lenses; Laboratoire LCS, Normandy, France), and 15 eyes of 10 patients with keratoconus were fitted with 16.5-mm mini-scleral lenses (Misa Lenses; Microlens Contactlens Technology, Arnhem, The Netherlands).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!