Purpose: To evaluate the intraocular pressure (IOP)-lowering effect and safety of up to 2 bimatoprost implant administrations versus selective laser trabeculoplasty (SLT).

Design: Phase 3 (Stage 2), randomized, 24-month, multicenter, patient- and efficacy evaluator-masked, paired-eye clinical trial (NCT02507687).

Participants: Patients (n = 183) with open-angle glaucoma or ocular hypertension inadequately managed with topical IOP-lowering medication for reasons other than efficacy.

Intervention: Patients received a single 360° SLT procedure in 1 eye and 10-µg bimatoprost implant administration in the contralateral eye. Initially, implant-treated eyes received a second implant at week 16 if safety criteria were met. After a protocol amendment, implant-treated eyes were retreated with flexible scheduling if IOP was >17 mm Hg and safety criteria were met.

Main Outcome Measures: The primary efficacy variable was IOP change from baseline, with primary timepoints at weeks 4, 12, and 24. Safety measures included treatment-emergent adverse events (TEAEs) and ocular safety measures.

Results: Mean (±SE) baseline IOP (mm Hg) was 25.2 ± 0.22 and 25.1 ± 0.22 in implant- and SLT-treated eyes, respectively. Least-squares mean (±SE) IOP reduction from baseline (mm Hg) for eyes treated with up to 2 implants versus SLT was 6.8 ± 0.28 versus 6.2 ± 0.28 at week 4, 6.9 ± 0.30 versus 6.4 ± 0.30 at week 12, and 6.9 ± 0.27 versus 6.5 ± 0.28 at week 24. The probability of not having required nonstudy (rescue) IOP-lowering treatment at days 360 and 720, respectively, was 67.5% and 50.2% for implant-treated eyes versus 68.7% and 60.6% for SLT-treated eyes. The most common ocular TEAE in both implant- and SLT-treated eyes was increased IOP attributed to wearing off of efficacy. Mean (±SE) percentage change in corneal endothelial cell density from baseline at month 24 was -6.2 ± 1.13% in implant-treated eyes (-7.9 ± 2.04% with fixed readministration; -5.2 ± 1.35% with flexible readministration) versus -3.1 ± 0.43% in SLT-treated eyes.

Conclusions: The bimatoprost implant demonstrated statistical and clinical noninferiority to SLT in IOP reduction from baseline at weeks 4, 12, and 24. In subgroup analysis, patients with flexible implant readministration met the same criteria. Both the implant and SLT demonstrated sustained (2-year) IOP lowering in many eyes. A flexible administration schedule improved the safety profile of the implant over the fixed administration schedule.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2024.12.026DOI Listing

Publication Analysis

Top Keywords

bimatoprost implant
16
implant-treated eyes
16
slt-treated eyes
12
eyes
9
implant
8
selective laser
8
laser trabeculoplasty
8
safety criteria
8
implant- slt-treated
8
iop reduction
8

Similar Publications

Background: Bimatoprost implant 10 µg is an intracameral, biodegradable implant that slowly releases bimatoprost to lower intraocular pressure (IOP). This study was designed to evaluate safety and the duration of the IOP-lowering effect after single and as-needed repeat administration of the bimatoprost implant in patients with open-angle glaucoma (OAG) and ocular hypertension (OHT).

Patients And Methods: This study is an interim analysis of an ongoing, prospective, open-label, multicenter study in patients with OAG or OHT who are inadequately managed with topical IOP-lowering medication for reasons other than efficacy.

View Article and Find Full Text PDF

Background And Objective: Bimatoprost implant 10 µg (Durysta) is an intracameral biodegradable implant that releases bimatoprost to lower intraocular pressure (IOP). The purpose of this study was to prospectively collect effectiveness and safety data after administration of the implant in patients with open-angle glaucoma or ocular hypertension.

Methods: This phase IV, multicenter, prospective, observational, open-label, 18-month study (ARGOS) enrolled adult patients with open-angle glaucoma or ocular hypertension who were scheduled to receive the bimatoprost implant in one or both eyes.

View Article and Find Full Text PDF

Sustained-release prostaglandin intracameral implants are new targeted treatment options for open-angle glaucoma or ocular hypertension that lower intraocular pressure (IOP) and reduce or eliminate the need for topical eye drops. To summarize evidence supporting prostaglandin intracameral implants for treatment of ocular hypertension or open angle glaucoma and identify patient populations most likely to benefit from these treatments. A PubMed search (1/1/2016 to 10/1/2024) was conducted to identify randomized, controlled clinical trials for bimatoprost 10-μg and travoprost 75-μg intracameral implants.

View Article and Find Full Text PDF

The bimatoprost intracameral implant (Durysta) offers a sustained-release approach to glaucoma management, providing consistent intraocular pressure (IOP) reduction over several months and reducing the need for daily topical therapies. This review evaluates its pharmacology, efficacy, and safety, using data from pivotal clinical trials and recent real-world studies. The implant achieves IOP reductions comparable to topical prostaglandin analogs, with benefits for patient adherence and fewer common side effects.

View Article and Find Full Text PDF

Purpose: To report a case of persistent bilateral sclerouveitis following bilateral bimatoprost implantation (Durysta) that required implant removal and oral steroid course.

Observation: A 75-year-old Caucasian male with no prior ocular inflammation experienced bilateral sclerouveitis post bilateral bimatoprost implantation. Despite implant removal from both eyes, the ocular inflammation persisted, showing cystoid macular edema in both eyes and exudative retinal detachment in the right.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!