Context: Recent advances in the development of rapid SARS-CoV-2 point of care (POC) testing provided an opportunity to aid clinical decision making in front-line healthcare settings. Perspectives of POC COVID-19 screening of pregnant women are under-researched.
Objective: To assess the impact of a SARS-CoV-2 POC testing platform implemented in a busy maternity hospital, with limited isolation capacity, during the third wave of the COVID-19 pandemic.
Methods: We conducted a before and after comparison of two consecutive 12-month periods and a retrospective evaluation of staff attitudes and POC test acceptance. Turnaround Time (TAT) and testing numbers were assessed by computer audit. Qualitative data was collected using confidential questionnaires.
Results: Mean TAT for the POC platform was 5.3x quicker (p < 0.001, chi-square test) when compared with local virus laboratory PCR testing. Samples sent for laboratory testing reduced by almost one third, following introduction of the POC device. A total of 27 staff members completed a POC testing satisfaction survey, which documented ease of use and benefits for diagnosis assistance, patient management and patient experience.
Conclusion: In this single-center maternity setting, POC testing decreased laboratory testing volume and SARS-Cov-2 result TAT for symptomatic women and those awaiting crucial investigations. POC COVID-19 investigation was deemed acceptable by the clinical team for facilitating patient placement, management, and use of limited isolation capacity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.idnow.2025.105024 | DOI Listing |
J Matern Fetal Neonatal Med
December 2025
Department of Obstetrics and Gynaecology, Riga Stradins University, Riga, Latvia.
Objectives: To compare the values of ultrasound and clinical parameters for predicting outcomes of induction of labor (IOL) among healthy nulliparous women with a singleton, term cephalic pregnancy.
Methods: The cervical length, cervical strain elastography, posterior cervical angle, head-perineum distance, Bishop score, and maternal parameters were assessed before IOL with a combined method-Foley catheter and Misoprostol perorally. The main outcome was vaginal delivery.
Infect Dis Now
January 2025
Department of Medical Microbiology and Virology. NHS Grampian, Aberdeen, UK. Electronic address:
Context: Recent advances in the development of rapid SARS-CoV-2 point of care (POC) testing provided an opportunity to aid clinical decision making in front-line healthcare settings. Perspectives of POC COVID-19 screening of pregnant women are under-researched.
Objective: To assess the impact of a SARS-CoV-2 POC testing platform implemented in a busy maternity hospital, with limited isolation capacity, during the third wave of the COVID-19 pandemic.
Rev Esp Cardiol (Engl Ed)
January 2025
Pediatric Cardiology Department, M3C National reference center, Hospital Necker- Enfants Malades, Assistance Publique-Hôpitaux de Paris, University Paris Cité, Paris, France.
Introduction And Objectives: Balloon atrial septostomy (BAS) improves oxygenation in neonates with transposition of the great arteries (TGA) and restrictive foramen ovale. Currently, there is a global shortage of dedicated BAS catheters, while new unmarked catheters have recently become available at some European centers. This study aimed to characterize BAS outcomes using the currently available BAS catheters in Europe.
View Article and Find Full Text PDFBMC Pregnancy Childbirth
January 2025
Department of Maternal and Child Nursing and Public Health, School of Nursing, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil.
Eur J Obstet Gynecol Reprod Biol
January 2025
Department of Obstetrics and Gynecology, Port-Royal Maternity, Cochin Hospital, Paris Cité University, APHP, Paris, France.
Objective: The objective was to evaluate the performance of two different obstetric ultrasound simulators in assessing the practical skills of trainees compared to the standard method of practical assessment conducted on pregnant women volunteers.
Methods: We performed a prospective observational study. Two simulators were compared: the Simbionix simulator which uses a mannequin and heteroevaluation and the OPUS simulator which uses optical positioning technology with automatic assessment.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!