Reliability of running gait variability measures calculated from inertial measurement units.

J Biomech

Sport and Physical Activity Research Centre, Sheffield Hallam University, Olympic Legacy Park, 2 Old Hall Rd, Sheffield S9 3TY, United Kingdom. Electronic address:

Published: January 2025

Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs). Nineteen runners completed six treadmill running trials on two occasions seven days apart. Stride time and sacral acceleration signals were obtained using IMUs. Stride time variability and complexity were calculated using the coefficient of variation (CV) and detrended fluctuation analysis (DFA), respectively. Sacral acceleration regularity was quantified using sample entropy with a range of input parameters m (vector length) and r (similarity threshold). Between-day reliability was assessed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change. Stride time CV displayed moderate relative reliability (ICC = 0.672), but with a large absolute minimum detectable change = 0.525 %, whilst stride time DFA-α displayed poor relative reliability (ICC = 0.457) and yielded large minimum detectable changes (≥ 0.208). Sample entropy displayed good relative reliability in mediolateral and resultant sacral acceleration signals for certain combinations of the parameters m and r, although again with large minimum detectable changes. Researchers should be cognisant of these reliability metrics when interpreting changes in running gait variability measures in clinical contexts.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2025.112515DOI Listing

Publication Analysis

Top Keywords

stride time
20
variability measures
16
sacral acceleration
16
minimum detectable
16
running gait
12
gait variability
12
measures calculated
12
relative reliability
12
reliability
8
calculated inertial
8

Similar Publications

Introduction: We aimed to compare gait between individuals with Alzheimer's disease (AD), dementia with Lewy bodies (DLB), and cognitively unimpaired (CU) individuals and to evaluate the association between gait and regional amyloid beta (Aβ) burden in AD and DLB.

Methods: We included 420 participants (70 AD, 70 DLB, 280 CU) in the Mayo Clinic Study of Aging (MCSA). Gait was assessed using a pressure-sensor walkway.

View Article and Find Full Text PDF

Portable monitoring devices based on Inertial Measurement Units (IMUs) have the potential to serve as quantitative assessments of human movement. This article proposes a new method to identify the optimal placements of the IMUs and quantify the smoothness of the gait. First, it identifies gait events: foot-strike (FS) and foot-off (FO).

View Article and Find Full Text PDF

Clinical Whole-Body Gait Characterization Using a Single RGB-D Sensor.

Sensors (Basel)

January 2025

German Center for Vertigo and Balance Disorders (DSGZ), LMU University Hospital, LMU Munich, 81377 Munich, Germany.

Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy.

View Article and Find Full Text PDF

Background: Virtual reality-based training has been widely used for post-stroke patients due to its positive effects on functional aspects by promoting brain plasticity.

Objective: This study aimed to investigate the effectiveness of gait training with virtual reality-based real-time feedback on motor function, balance, and spatiotemporal gait parameters in post-stroke patients.

Methods: Fifteen patients ( = 15) with chronic stroke were randomly assigned to either the virtual reality-based real-time feedback with treadmill gait training (experimental group = 8) or the treadmill gait training (control group = 7).

View Article and Find Full Text PDF

Initial Contact with Forefoot or Rearfoot in Spastic Patients After Stroke-Three-Dimensional Gait Analysis.

Neurol Int

January 2025

Laboratório de Marcha, Centro de Medicina de Reabilitação de Alcoitão, 2649-506 Alcabideche, Portugal.

Background/objectives: Post-stroke hemiparetic gait often presents with asymmetric patterns to compensate for stability deficits. This study examines gait differences in chronic stroke patients with spastic hemiparesis based on initial foot contact type-forefoot versus rearfoot.

Methods: Thirty-four independently walking spastic hemiparetic patients were retrospectively analyzed.

View Article and Find Full Text PDF