Contrast media, including iodinated contrast media and gadolinium-based contrast agents, are commonly administered pharmaceuticals with excellent safety profiles. However, a minority of the population may experience a hypersensitivity reaction following intravenous administration. Hypersensitivity reactions can be immediate or delayed, and range from mild, such as urticaria, to severe, including anaphylaxis. There is emerging evidence that longstanding pretreatment protocols, such as diphenhydramine and corticosteroids, are ineffective and have the potential for side effects and other harms. Moreover, the evidence for efficacy on which this practice is based is weak and outdated. A joint collaborative working group of representatives from the Canadian Association of Radiologists and the Canadian Society of Allergy and Clinical Immunology was assembled to inform medical professionals and hospital policies regarding hypersensitivity reactions to contrast media. The objectives of the working group were to provide an overview of the epidemiology, physiology, risk factors, and types of hypersensitivity reactions; to synthesize the evidence for pretreatment strategies that minimize the risk of a breakthrough reaction for both iodinated contrast media and gadolinium-based contrast agents; to review the allergy investigations used to evaluate patients with a history of severe hypersensitivity reaction; and to provide an overview of existing guidelines. Following appraisal of the evidence, the working group established recommendations based on consensus in this practice guidance.

Download full-text PDF

Source
http://dx.doi.org/10.1177/08465371241311253DOI Listing

Publication Analysis

Top Keywords

contrast media
20
hypersensitivity reactions
12
working group
12
practice guidance
8
iodinated contrast
8
media gadolinium-based
8
gadolinium-based contrast
8
contrast agents
8
hypersensitivity reaction
8
provide overview
8

Similar Publications

Sentinel lymph node (SLN) detection has been widely investigated in recent years as a part of the surgical staging of women with endometrial cancer (EC), gradually overtaking lymphadenectomy (LND) in this respect. In this study, thirty EC patients, assumed as stage I, were investigated using superparamagnetic iron oxide (SPIO) as a tracer for SLN detection followed by LND. The endpoints of this research were the proportion of successful SLN detection, the average number of SLNs per patient, the percentage of bilaterally detected SLNs, and the proportion of metastatic SLNs.

View Article and Find Full Text PDF

Risk of acute kidney injury following repeated contrast exposure in trauma patients.

Eur J Trauma Emerg Surg

January 2025

Division of Trauma and Emergency Surgery, Department of Surgery, Chang Gung Memorial Hospital, No. 5, Fuxing St., Guishan Dist., Taoyuan City, 333, Taiwan.

Purpose: This study investigates the risk of contrast-associated acute kidney injury (CA-AKI) in trauma patients, focusing on the impact of cumulative contrast medium doses.

Methods: A retrospective review was conducted at a level 1 trauma center (2019-2021). The study included patients who underwent intravascular contrast-enhanced examinations for torso trauma within 7 days post-injury.

View Article and Find Full Text PDF

Technical and clinical reasons for negative skin test results following intradermal testing of contrast media.

Eur J Radiol

January 2025

Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University of Bern, Freiburgstrasse, Bern 3010 Switzerland. Electronic address:

View Article and Find Full Text PDF

Aims: To develop a transformer-based generative adversarial network (trans-GAN) that can generate synthetic material decomposition images from single-energy CT (SECT) for real-time detection of intracranial hemorrhage (ICH) after endovascular thrombectomy.

Materials: We retrospectively collected data from two hospitals, consisting of 237 dual-energy CT (DECT) scans, including matched iodine overlay maps, virtual noncontrast, and simulated SECT images. These scans were randomly divided into a training set (n = 190) and an internal validation set (n = 47) in a 4:1 ratio based on the proportion of ICH.

View Article and Find Full Text PDF

Objectives: To evaluate the effectiveness of breast MRI, including diffusion-weighted imaging (DWI), in detecting residual lesions in patients with malignancy after excisional biopsy.

Methods: From January 2018 to December 2023, 3T breast MRI was performed to assess lesion morphology, residual size, and enhancement kinetics. The apparent diffusion coefficient (ADC) values were measured, and the diagnostic outcomes of CE-MRI, CE-MRI with DWI, mammography (MG), and ultrasound (US) were compared with clinical and histopathological data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!