Accuracy of Rhythm Diagnostic Systems' MultiSense in Detection of Arterial Oxygen Saturation and Respiratory Rate During Hypoxia in Humans: Effects of Skin Color and Device Localization.

Sensors (Basel)

Biomedicine Research Center of Strasbourg (CRBS), UR 3072, "Mitochondria, Oxidative Stress and Muscle Plasticity", Faculty of Medicine, University of Strasbourg, 67000 Strasbourg, France.

Published: December 2024

The continuous monitoring of oxygen saturation (SpO) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations. In this study, we investigated the reliability of the new Multisense pulse oximetry system compared to a reference pulse oximeter (Vyntus CPX Pulse Oximeter) during hypoxia. In a population of sixteen healthy male subjects (mean age: 31.5 ± 7.0 years, BMI: 24.9 ± 3.6 kg/m², and 35% with darker skin tones), simultaneous SpO and RR measurements were collected over 12.4 h, during which FiO was progressively reduced from 21% to 10.5%. The average root mean square error (ARMS) of SpO for Multisense placed on the back and chest was 2.94% and 2.98%, respectively, with permutation testing confirming a significant ARMS below 3.5% for both positions and no statistically significant difference in the ARMS between patch placements. Positive correlations and acceptable accuracy between devices were observed at both locations (r = 0.92, < 0.001 and r = 0.90, < 0.001 for back and chest placements, respectively). Bland-Altman analysis further indicated limits of agreement that support consistency across placements, with similar agreement levels noted across skin tones. Similar findings were obtained with the RR measurements. In conclusion, Multisense demonstrated robust accuracy in measuring SpO and RRs during hypoxia in humans comparable to standard hospital-grade equipment. The effectiveness of the findings suggests that this wearable device is a valuable tool for the continuous monitoring of SpO and RRs, potentially enhancing patient safety and optimizing hospital resource allocation. Nevertheless, to overcome study limitations and allow generalized use, further work on a larger population sample, including more subjects with a high phototype and desaturation below 80%, would be useful.

Download full-text PDF

Source
http://dx.doi.org/10.3390/s25010127DOI Listing

Publication Analysis

Top Keywords

oxygen saturation
8
hypoxia humans
8
continuous monitoring
8
pulse oximeter
8
skin tones
8
spo rrs
8
spo
6
accuracy rhythm
4
rhythm diagnostic
4
diagnostic systems'
4

Similar Publications

Background: Although both the lateral sagittal and costoclavicular approaches are applied at the cord level in the infraclavicular region, there is a major difference between the distributions of the two approaches. We aimed to investigate the effects of this different distribution on tissue perfusion and oxygenation.

Methods: Sixty patients undergoing elective elbow, forearm, wrist and hand surgery under infraclavicular brachial plexus block were included in the study.

View Article and Find Full Text PDF

Background And Aims: Ward-delivered non-invasive respiratory supports (NIRS) (conventional oxygen therapy (COT), high-flow nasal oxygen (HFNO), continuous positive airway pressure (CPAP) and non-invasive ventilation (NIV)), are often used to treat hospitalised patients with acute respiratory failure (ARF) both in high acuity and general wards. This study aimed to describe the processes of care adopted and examine patient outcomes from a specialist, ward-delivered NIRS service caring for people with COVID-19 in general wards or in a respiratory care unit (RCU).

Methods: A cohort study was undertaken including all consecutive patients admitted to a quaternary hospital with ARF secondary to COVID-19 and requiring ward-delivered NIRS between 28 February 2020 and 18 March 2022.

View Article and Find Full Text PDF

Ultra-broadband photodetectors (UB-PDs) are essential in medical applications, public safety monitoring, and various other fields. However, developing UB-PDs covering multiple bands from ultraviolet to medium infrared remains a challenge due to material limitations. Here, a mixed-dimensional heterojunction composed of 2D WS/monodisperse hexagonal stacking (MHS) 3D PdTe particles on 3D Si is proposed, capable of detecting light from 365 to 9600 nm.

View Article and Find Full Text PDF

Objective: Limited information is available regarding the associations between upper extremity function, activities of daily living (ADLs), and functional capacity in patients with heart failure with reduced ejection fraction (HFrEF). This study aimed to investigate the associations between upper extremity function, ADLs, and functional capacity in patients with HFrEF.

Methods: This cross-sectional study included 31 patients with HFrEF.

View Article and Find Full Text PDF

Obstructive sleep apnoea (OSA) is a sleep-related breathing condition that involves the presence of episodic disruptions to the sleeping pattern due to partial or complete airway obstruction. There are a range of treatment options that exist to alleviate the symptoms of this condition including CPAP, mandibular advancement, and maxillary expansion techniques. This systematic review and meta-analysis of published articles aims to determine if rapid maxillary expansion ("RME") is an effective treatment option in the management of OSA, using quantitative parameters of AHI and SpO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!