: Glucagon-like peptide-1 receptor agonists (GLP-1RAs) have demonstrated significant efficacy in obesity treatment beyond their original development for type-2 diabetes management. This comprehensive study investigated the relationship between GLP-1RA use and cancer incidence in individuals with obesity across a 5-year follow-up period. : We conducted a large-scale cohort study using the TriNetX US Collaborative Network database (2013-2023) examining adult patients with obesity. The study utilized propensity score matching to pair GLP-1RA-treated patients with controls (1:1) using the nearest neighbor method. Cancer incidence served as the primary outcome measure over the 5-year follow-up, with subgroup analyses considering individual GLP-1RA agents, patient sex, and BMI categories. : Analysis revealed significant cancer-risk reductions associated with GLP-1RA use across multiple cancer types compared to matched controls. Notable risk reductions were observed in gastrointestinal (HR 0.67, 95% CI 0.59-0.75), skin (HR 0.62, 95% CI 0.55-0.70), breast (HR 0.72, 95% CI 0.64-0.82), female genital (HR 0.61, 95% CI 0.53-0.71), prostate (HR 0.68, 95% CI 0.58-0.80), and lymphoid/hematopoietic cancers (HR 0.69, 95% CI 0.60-0.80). Semaglutide demonstrated superior protective effects, particularly in gastrointestinal cancers (HR 0.45, 95% CI 0.37-0.53). Conversely, liraglutide showed increased risks for thyroid (HR 1.70, 95% CI 1.03-2.82) and respiratory cancers (HR 1.62, 95% CI 1.13-2.32). : This research provides compelling evidence for GLP-1RA's potential role in cancer-risk reduction, with semaglutide showing particularly promising results. The differential effects observed among GLP-1RA agents emphasize the importance of personalized medicine approaches. These findings suggest significant implications for clinical practice and future research in both obesity management and cancer prevention.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11720624PMC
http://dx.doi.org/10.3390/cancers17010078DOI Listing

Publication Analysis

Top Keywords

95%
9
differential effects
8
receptor agonists
8
cancer incidence
8
5-year follow-up
8
glp-1ra agents
8
cancer
5
obesity
5
effects glp-1
4
glp-1 receptor
4

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!