Using a newly developed tool head with an additional rotational axis and a wire feed, wires can be directly processed in the fused filament fabrication (FFF) process. Thus, electrical structures such as conductive paths, coils, heating elements, or sensors can be integrated into polymer parts. However, the accuracy of the wire deposition in curved sections of the print track is insufficient. To improve the wire position, a geometric correction model was set up, converted into G-code, and validated using test prints for different wire parameters. For this, a sample of printed arcs was evaluated regarding wire position and embedding quality using various visual methods. This also determined the optimal cooling time for the model. The process parameters extrusion coefficient and feed were then varied to identify optimal process parameters for a stable and at the same time efficient process. By varying the wire (copper, constantan) and polymer material (PLA, PETG), the model was checked for general validity. It was found that the position of the ø 0.2 mm wire can be improved with the correction model. Different sets of parameters can be found that enable good quality of embedding and wire position.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/ma18010041 | DOI Listing |
Am J Orthod Dentofacial Orthop
January 2025
Department of Orthodontics, Bauru Dental School, University of São Paulo, Bauru, Brazil.
Introduction: The objective of this study was to compare the dental and skeletal changes promoted by the miniscrew-anchored cantilever and pendulum appliance for Class II correction.
Methods: This retrospective study involved 52 patients with Class II malocclusion divided into 2 groups according to the treatment received: the miniscrew group (MG) with 23 patients (14 females and 9 males; mean initial age of 12.42 years) treated using the miniscrew-anchored cantilever, and the pendulum group (PG) with 29 patients (21 females and 8 males; mean initial age of 13.
Eur J Neurol
January 2025
Department of Neurology, RWTH Aachen University, Aachen, Germany.
Background: Friedreich ataxia is a rare neurodegenerative disorder caused by frataxin deficiency. Both underweight and overweight occur in mitochondrial disorders, each with adverse health outcomes. We investigated the longitudinal evolution of anthropometric abnormalities in Friedreich ataxia and the hypothesis that both weight loss and weight gain are associated with faster disease progression.
View Article and Find Full Text PDFJ Clin Med
January 2025
Hospital Virgen de la Arrixaca, 30120 Murcia, Spain.
Accurate segmentation of the left ventricular myocardium in cardiac MRI is essential for developing reliable deep learning models to diagnose left ventricular non-compaction cardiomyopathy (LVNC). This work focuses on improving the segmentation database used to train these models, enhancing the quality of myocardial segmentation for more precise model training. We present a semi-automatic framework that refines segmentations through three fundamental approaches: (1) combining neural network outputs with expert-driven corrections, (2) implementing a blob-selection method to correct segmentation errors and neural network hallucinations, and (3) employing a cross-validation process using the baseline U-Net model.
View Article and Find Full Text PDFJ Clin Med
December 2024
The David J Apple Center for Vision Research, Department of Ophthalmology, Heidelberg University Eye Clinic, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
This laboratory study aims to assess the effects of misaligning different trifocal intraocular lenses (IOLs) under varying spectral and corneal spherical aberration (SA) conditions. With an IOL metrology device under monochromatic and polychromatic conditions, the following models were studied: AT ELANA 841P, AT LISA Tri 839MP, FineVision HP POD F, Acrysof IQ PanOptix, and Tecnis Synergy ZFR00V. The SA was simulated using an aberration-free and average-SA cornea.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Ophthalmology, Medical University of Warsaw, Sierakowskiego 13, 01-756 Warsaw, Poland.
To evaluate visual acuity improvement and identify contributing factors in patients with severe keratitis affecting both virgin and transplanted corneas, treated at a hospital. A retrospective analysis was conducted on 497 patients with unilateral corneal ulcers treated at a tertiary referral center between 2008 and 2023. Data included distance (BCVA) and near best-corrected visual acuity at initial presentation and at discharge, treatments before hospital admission, demographic details, risk factors, clinical signs and symptoms, ancillary test results, and management strategies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!