Herein, we report the methodological impact on the curing kinetics of bone cement based on polymer nanocomposites prepared using different methods. Poly (styrene--methylmethacrylate)-2D nanofiller nanocomposites (P(S-MMA)-2D Nanofiller) were prepared using bulk and suspension polymerization methods to study the effect of the different methods. The prepared nanocomposites were well-characterized for chemical, thermal, mechanical, and structural characteristics using Fourier Transform Infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC), nano-indentation, and scanning electron microscopy (SEM) techniques, respectively. The FT-IR results confirmed the successful formation of the polymer nanocomposites. The DSC results showed that the prepared nanocomposites have higher thermal stabilities than their copolymer counterparts. The nano-indentation results revealed that the elastic modulus of the copolymer nanocomposites (bulk polymerization) was as high as 7.89 GPa, and the hardness was 0.219 GPa. Incorporating the 2D nanofiller in the copolymer matrix synergistically enhances the thermo-mechanical properties of the bone cement samples. The polymer nanocomposites prepared using the suspension polymerization method exhibit faster-curing kinetics (15 min) than those prepared using the bulk polymerization (120-240 min) method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/polym17010116 | DOI Listing |
J Clin Med
January 2025
Discipline of Physiotherapy, Faculty of Health Sciences, European University Miguel de Cervantes, C del Padre Julio Chevalier 2, 47012 Valladolid, Spain.
: Hip fractures are prevalent among the elderly and impose a significant burden on healthcare systems due to the associated high morbidity and costs. The increasing use of intramedullary nails for hip fracture fixation has inadvertently introduced risks; these implants can alter bone elasticity and create stress concentrations, leading to peri-implant fractures. The aim of this study is to investigate the outcomes of peri-implant hip fractures, evaluate the potential causes of such fractures, determine the type of treatment provided, assess the outcomes of said treatments, and establish possible improvement strategies.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
College of Science and General Studies, AlFaisal University, P.O. Box 50927, Riyadh 11533, Saudi Arabia.
Herein, we report the methodological impact on the curing kinetics of bone cement based on polymer nanocomposites prepared using different methods. Poly (styrene--methylmethacrylate)-2D nanofiller nanocomposites (P(S-MMA)-2D Nanofiller) were prepared using bulk and suspension polymerization methods to study the effect of the different methods. The prepared nanocomposites were well-characterized for chemical, thermal, mechanical, and structural characteristics using Fourier Transform Infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC), nano-indentation, and scanning electron microscopy (SEM) techniques, respectively.
View Article and Find Full Text PDFJ Cosmet Dermatol
January 2025
College of Medicine, Department of Dermatology, Imam Mohammad Ibn Saud University, Riyadh, Saudi Arabia.
Background: Acne is a common condition observed in adolescents and in most severe acne the scars develop. There are numerous treatment options for acne scars. However, no standardized guidelines have been established to guide physicians in the optimal treatment of acne scars.
View Article and Find Full Text PDFClin Spine Surg
December 2024
Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjyuku, Tokyo.
Study Design: Multicenter retrospective cohort study.
Objective: To evaluate the efficacy and safety of using cement-augmented pedicle screw (CAPS) fixation only for the cephalad and caudal vertebral bodies.
Summary Of Background Data: Pedicle screw fixation is less effective in patients with low-quality bone.
PLoS One
January 2025
Departamento de Reología y Mecánica de Materiales, Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México Ciudad Universitaria, Ciudad de México, México.
A hybrid coating made of poly (methyl methacrylate) with SiO2-TiO2 particles (PMMA/SiO2-TiO2) has been developed for use as a coating on nanosatellites, evaluating its resistance to high vacuum by quantifying its weight loss. The coating was applied on an Al 7075 aluminum substrate used for the aerospace sector. PMMA/SiO2-TiO2 hybrid coatings were prepared using sol-gel reaction in situ assisted with sonochemistry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!