This study compared the quality of northern pike eggs collected using traditional methods (hand stripping) and pneumatic methods (air stripping). The effects of different activation solutions (0.4% NaCl, 0.8% NaCl, and hatchery water) on egg fertilization under controlled conditions were also investigated. After egg collection, the Pseudo-Gonado-Somatic Index (PGSI) was measured; the PGSI values in the samples obtained using the pneumatic method (13.8 ± 3.9%) were lower, but did not differ statistically from those obtained by hand stripping (16.5 ± 5.4%). The 0.4% NaCl solution proved to be the most effective for sperm activation, as assessed by the Computer-Assisted Sperm Analysis (CASA) system, compared to the 0.8% NaCl solution. The pneumatic method achieved a higher egg collection efficiency (93.7% occlusion) than the traditional method, with significant differences observed in groups activated with water. The average hatching percentage of larvae was 89.5% in groups using the pneumatic method, compared to 71.2% in the traditional groups, highlighting the advantages of this modern approach. The application of the pneumatic method and 0.4% NaCl for the artificial fertilization of northern pike resulted in higher fertilization and hatching rates compared to other techniques, making this method a promising option for the artificial reproduction of other fish species.

Download full-text PDF

Source
http://dx.doi.org/10.3390/ani15010008DOI Listing

Publication Analysis

Top Keywords

pneumatic method
16
northern pike
12
04% nacl
12
sperm activation
8
hand stripping
8
08% nacl
8
egg collection
8
nacl solution
8
method
6
pneumatic
5

Similar Publications

This study compared the quality of northern pike eggs collected using traditional methods (hand stripping) and pneumatic methods (air stripping). The effects of different activation solutions (0.4% NaCl, 0.

View Article and Find Full Text PDF

Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.

View Article and Find Full Text PDF

Background: Tricuspid anteroposterior patch (TRAPP) repair aims to address shortcomings of traditional annuloplasty in functional tricuspid regurgitation by selectively enlarging and translocating the anterior and posterior leaflets, but optimal patch width has not been identified.

Methods: An ex vivo model of the tricuspid valve was established in fresh porcine hearts by pneumatic pressurization of the ventricles. TRAPP repair was performed with patches of varying width (group 1, 1.

View Article and Find Full Text PDF

Background And Purpose: Throwing a baseball involves intense exposure of the arm to high speeds and powerful forces, which contributes to an increasing prevalence of arm injuries among athletes. Traditional rigid exoskeletons and rehabilitation equipment frequently lack portability, safety, ergonomic design, and affordability. Traditional rehabilitation approaches frequently require therapist monitoring, resulting in therapy delays.

View Article and Find Full Text PDF

In this work, a cost-effective, scalable pneumatic silicone actuator array is introduced, designed to dynamically conform to the user's skin and thereby alleviate localised pressure within a prosthetic socket. The appropriate constitutive models for developing a finite element representation of these actuators are systematically identified, parametrised, and validated. Employing this computational framework, the surface deformation fields induced by 270 variations in soft actuator array design parameters under realistic load conditions are examined, achieving predictive accuracies within 70 µm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!