Current state-of-the-art tools for analysing extracellular vesicles (EVs) offer either highly sensitive but unidimensional bulk measurements of EV components, or high-resolution multiparametric single-particle analyses which lack standardization and appropriate reference materials. This limits the accuracy of the assessment of marker abundance and overall marker distribution amongst individual EVs, and finally, the understanding of true EV heterogeneity. In this study, we aimed to define the standardized operating procedures and reference material for fluorescent characterization of EVs with two commonly used EV analytical platforms-nanoparticle tracking analysis (NTA) and nano-flow cytometry (nFCM). We achieved quantitative fluorescence analyses on ZetaView NTA and NanoAnalyzer nFCM instruments, by utilizing yellow-green FluoSpheres (FS) with assigned ERF (equivalent reference fluorophore) values. This standardization technique allowed for fluorescent EV signal to be expressed in ERF units (indicative of bound fluorescent antibodies per EV), thus enabling measurement of target protein marker abundance on individual EVs, and in the whole EV population. The NTA's and nFCM's limits of detection (LoD) were evaluated at 21 and 9 Alexa Fluor 488 (AF488) molecules, respectively. To complement the limited quantification of markers expressed in a few copies per single EV, in-line bulk fluorescence measurements with a plate reader were performed. This provided absolute marker quantification and more insightful analyses of EV heterogeneity and marker stoichiometry. The standardization method outlined in this work unlocks the full analytical potential of NTA and nFCM, enabling cross-platform data comparison. At the same time, it highlights some of the technical challenges and considerations and thus contributes to the ongoing efforts towards the development of EV analytical tools.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11707551PMC
http://dx.doi.org/10.1002/jex2.70031DOI Listing

Publication Analysis

Top Keywords

tracking analysis
8
nano-flow cytometry
8
extracellular vesicles
8
marker abundance
8
individual evs
8
marker
5
quantitative fluorescent
4
fluorescent nanoparticle
4
nanoparticle tracking
4
analysis nano-flow
4

Similar Publications

The northern part of Asia, including Siberia, the Mongolian Plateau, and northern China, is not only a crossroads for population exchange on the Eurasian continent but also an important bridge connecting the American continent. This region holds a unique and irreplaceable significance in exploring the origins of humanity, tracking human migration routes, and elucidating evolutionary mechanisms. Despite the limited number of samples unearthed, varying preservation conditions, and constraints of technical means, our understanding of the interactions among populations in northern Asia is still in its infancy.

View Article and Find Full Text PDF

Play is critical to child development. In early childhood, object play evolves from exploratory behavior to complex symbolic play. Engagement during play, particularly joint engagement, is essential for learning and social interaction.

View Article and Find Full Text PDF

The diffusion motions of individual polymer aggregates in disordered porous media were visualized using the single-particle tracking (SPT) method because the motions inside porous media play important roles in various fields of science and engineering. In the aggregates diffused on the surfaces of pores, continuous adsorption and desorption processes were observed. The relationship between the size of the aggregates and pore size was analysed based on diffusion coefficients, moment scaling spectrum (MSS) slope analysis, and diffusion anisotropy analysis.

View Article and Find Full Text PDF

Background: Dextro-transposition of the great arteries (dTGA) stands out as a prevalent cyanotic congenital heart defect (CHD), characterized by an intricate reversal in the arrangement of the major arteries. In the past, several surgical procedures have been used to treat dTGA, including the atrial switch. Although the method is no longer used, survivors of the procedure still living among us.

View Article and Find Full Text PDF

Current state-of-the-art tools for analysing extracellular vesicles (EVs) offer either highly sensitive but unidimensional bulk measurements of EV components, or high-resolution multiparametric single-particle analyses which lack standardization and appropriate reference materials. This limits the accuracy of the assessment of marker abundance and overall marker distribution amongst individual EVs, and finally, the understanding of true EV heterogeneity. In this study, we aimed to define the standardized operating procedures and reference material for fluorescent characterization of EVs with two commonly used EV analytical platforms-nanoparticle tracking analysis (NTA) and nano-flow cytometry (nFCM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!