Evaluating the diagnostic accuracy of fetal scalp blood sampling: A retrospective cohort study.

Eur J Obstet Gynecol Reprod Biol

Maternal and Fetal Health Research Centre, Division of Developmental Biology and Medicine, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, UK; Saint Mary's Hospital, Manchester University NHS Foundation Trust, UK.

Published: December 2024

Introduction: Fetal scalp blood sampling (FSBS) can be used as an adjunctive test, in the presence of a pathological intrapartum fetal heart rate trace, to provide evidence of fetal acidaemia. The role of FSBS remains controversial, this study evaluates the diagnostic accuracy of FSBS at determining various adverse neonatal outcomes.

Method: A retrospective cohort analysis of FSBS undertaken < 1 h from birth in a single UK centre in 2016 and 2017. An FSBS pH of < 7.20 was abnormal. Adverse outcomes were: low umbilical cord artery (UCA) pH (<7.20), neonatal acidaemia (UCA pH < 7.05), and 5-minute Apgar score < 7. Regression was performed to adjust for potential confounding variables. Receiver operator characteristic (ROC) curves were calculated and test accuracy, including sensitivity and specificity were determined, for an abnormal FSBS pH and adverse neonatal outcomes.

Results: Data from 407 births occurring ≤ 60 min from FSBS were analysed. To predict neonatal acidaemia, FSBS had an area under the ROC (AUROC) of 0.77 (95 % CI 0.65, 0.88). To predict low Apgar scores, FSBS had an AUROC of 0.80 (95 % CI 0.70, 0.90). In general, an FSBS pH of < 7.20 has low sensitivity and high specificity for neonatal acidaemia (28.6 % and 85.5 % respectively) and for low Apgar scores (38.1 %, 90.82 %).

Discussion: As FSBS has high specificity for adverse neonatal outcomes, it could be used to exclude asphyxia as it has a high NPV. Further research is required to evaluate whether other means of FSBS assessment, e.g. lactate, have better diagnostic test accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejogrb.2024.12.039DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
8
fetal scalp
8
scalp blood
8
blood sampling
8
retrospective cohort
8
evaluating diagnostic
4
fetal
4
accuracy fetal
4
sampling retrospective
4
cohort study
4

Similar Publications

Background: Segmentation models for clinical data experience severe performance degradation when trained on a single client from one domain and distributed to other clients from different domain. Federated Learning (FL) provides a solution by enabling multi-party collaborative learning without compromising the confidentiality of clients' private data.

Methods: In this paper, we propose a cross-domain FL method for Weakly Supervised Semantic Segmentation (FL-W3S) of white blood cells in microscopic images.

View Article and Find Full Text PDF

To evaluate the accuracy of home self-monitoring portable blood glucose meters, we analyzed the current problems of patients using portable blood glucose meters and put forward reasonable suggestions. A self-designed questionnaire was used to survey 142 patients and 132 healthcare professionals. The questionnaire consisted of 16 items with an overall score ranging from 1 to 13 (with a higher score indicating better experience).

View Article and Find Full Text PDF

The aim of this study was to evaluate the clinical benefits and outcomes of adjuvant radiation therapy on adrenocortical carcinoma (ACC) patients. All patients with ACC that were reported between 2010 and 2015 were identified from the Surveillance, Epidemiology, and End Results database. A forward-stepwise Cox proportional hazards regression was used to identify independent risk factors.

View Article and Find Full Text PDF

Background: The performance of quantitative pupillary light reflex (qPLR) and the neurological pupil index (NPi) was used to predict neurological outcomes in cardiac arrest (CA) patients.

Methods: Eligible studies on the ability of the qPLR and NPi to predict neurological outcomes in CA patients were searched from the PubMed and China National Knowledge Infrastructure databases until July 2023. The pooled odds ratio (OR) and its 95% confidence interval (95% CI), area under the curve, sensitivity analysis, and publication bias were analyzed via Stata 14.

View Article and Find Full Text PDF

Background: The aim is to develop age-specific anti-Müllerian hormone screening criteria for polycystic ovary syndrome to facilitate the early detection and diagnosis of the condition, and to subsequently evaluate the screening criteria.

Methods: A retrospective analysis was performed on patient data from Hangzhou Women's Hospital between July 2021 and August 2024. The use of restricted cubic spline analysis helped identify age-related inflection points, which were crucial for segmenting the patient population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!