Selecting an appropriate microcatheter tip shape for paraclinoid aneurysms is difficult. Therefore, we devised an original simple and uniform three-dimensional (3D) spiral-shaping method of microcatheter and validated the characteristics and usefulness of this method for coil embolization of paraclinoid aneurysms using patient-specific silicone models. These silicone models were produced based on clinical data from four patients with four paraclinoid aneurysms that underwent endovascular treatment using the 3D spiral-shaping method. These models were classified into four types: superior, medial, inferior, and lateral corresponding to the aneurysm protrusion and locations (C3 or C2 segments by Fisher's classification). Employing a pulsatile pump setup, two operators assessed the following items: navigation methods (pull and wire guiding), catheterization times, microcatheter tip position in the aneurysm, and the feasibility of inserting a framing coil by simple technique compared with three other shapes (straight, 90, pigtail). Three-dimensional spiral-shaped microcatheter could be placed in the medial and inferior type models of C3 segments and superior type model of C2 segment by the pullback method. Catheterization times using a 3D spiral-shaped catheter were significantly shorter than other shaped ones in the superior type models. No significant difference was found in another silicone model. Three-dimensional spiral- and pigtail-shaped catheters tended to position the tip at the center of the aneurysm. In conclusion, 3D spiral-shaped microcatheter was especially effective for the superior projected aneurysm at the C2 segment. The 3D spiral-shaping method can provide easy and secure navigation of the microcatheter into the paraclinoid aneurysms, ensuring optimal positioning for coil insertion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11704776PMC
http://dx.doi.org/10.18999/nagjms.86.4.655DOI Listing

Publication Analysis

Top Keywords

paraclinoid aneurysms
20
spiral-shaping method
16
silicone models
12
three-dimensional spiral-shaping
8
method microcatheter
8
microcatheter paraclinoid
8
medial inferior
8
catheterization times
8
spiral-shaped microcatheter
8
type models
8

Similar Publications

Selecting an appropriate microcatheter tip shape for paraclinoid aneurysms is difficult. Therefore, we devised an original simple and uniform three-dimensional (3D) spiral-shaping method of microcatheter and validated the characteristics and usefulness of this method for coil embolization of paraclinoid aneurysms using patient-specific silicone models. These silicone models were produced based on clinical data from four patients with four paraclinoid aneurysms that underwent endovascular treatment using the 3D spiral-shaping method.

View Article and Find Full Text PDF

Background: The stent-assisted coiling (SAC) and flow-diverter stent (FDS) techniques are widely used in the endovascular treatment of paraclinoid aneurysms. This article compares the occlusion rate, periprocedural complications, and clinical outcomes of SAC and FDSs.

Methods: Between January 2010 and December 2020, a systematic search of electronic databases identified 2283 articles for screening.

View Article and Find Full Text PDF
Article Synopsis
  • The study examines treatment strategies for unruptured large/giant paraclinoid aneurysms in Japan, focusing on methods like coiling, clipping, parent artery occlusion (PAO), and flow diverters (FDs).
  • Coiling was the most commonly used method for large aneurysms, while PAO was preferred for giant ones; all treatments showed high occlusion rates but had varying complications.
  • The findings suggest that while all methods are effective, FDs emerge as the best option due to their high occlusion rate and lower complication and retreatment risks.
View Article and Find Full Text PDF

Discriminators of Paraclinoid Aneurysm Rupture Based On Morphological Computer-Assisted Semiautomated Measurement (CASAM) and Hemodynamic Analysis.

Clin Neuroradiol

December 2024

Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, 100053, Beijing, China.

Background: Paraclinoid aneurysms, arising from the proximal dural ring and extending to the origin of the posterior communicating artery of the internal carotid artery (ICA), represent a significant proportion of all intracranial aneurysms (IAs). Accurate prediction of the rupture risk of paraclinoid aneurysms is crucial for optimal management. The objective of this study was to identify risk factors for the rupture of paraclinoid aneurysms on the basis of computer-assisted semiautomated measurement (CASAM) and hemodynamics.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the transorbital approach (TO) for accessing vascular lesions, specifically the carotid and middle cerebral arteries, using cadaveric specimens to understand its feasibility for vascular clipping.
  • Dissection involved a stepwise TO method that included procedures like lateral orbital craniectomy and anterior clinoidectomy, allowing for exposure of various vascular segments and cranial nerves.
  • Findings suggest that the TO approach effectively exposes key artery segments, indicating its potential use in treating paraclinoid and posterior communicating aneurysms.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!