A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implant failure of the Compress prosthesis: a case report. | LitMetric

Implant failure of the Compress prosthesis: a case report.

J Med Case Rep

Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi, 466-8550, Japan.

Published: January 2025

Background: The Compress is designed to achieve bone formation and stability by applying pressure at the bone-implant interface, minimizing the likelihood of aseptic loosening, which is a complication of stem implants. Herein, we report two cases of implant failure using the Compress.

Case Presentation: Case 1 describes a 36 year-old Japanese man who underwent extraarticular tumor resection, Compress arthroplasty, and reconstruction with a gastrocnemius flap after preoperative chemotherapy for a secondary malignant giant cell tumor in the right distal femur. Postoperatively, partial weight-bearing was started at 6 weeks, and full weight-bearing was allowed at 10 weeks. One year after the surgery, a fall caused implant failure. No bone formation at the implant-bone interface was observed on radiographs immediately prior to the failure. Bone formation was achieved at the interface 1 year after revision arthroplasty, and the patient was able to walk unassisted with a brace. Case 2 describes a 14 year-old Japanese boy who underwent wide surgical resection of osteosarcoma in the left tibia, Compress arthroplasty, and reconstruction with a gastrocnemius flap after preoperative chemotherapy. The postoperative weight-bearing schedule was the same as that of case 1. One year after the surgery, the patient experienced implant failure. A revision arthroplasty was performed. One year after revision surgery, the patient was able to walk unassisted.

Conclusion: Although the risk factors for Compress failure remain unknown, it is important to consider patient characteristics that may inhibit bone formation, implant selection, postoperative loading timing, and radiographs of bone formation at the implant interface when using the Compress.

Download full-text PDF

Source
http://dx.doi.org/10.1186/s13256-024-05012-1DOI Listing

Publication Analysis

Top Keywords

bone formation
20
implant failure
16
case describes
8
compress arthroplasty
8
arthroplasty reconstruction
8
reconstruction gastrocnemius
8
gastrocnemius flap
8
flap preoperative
8
preoperative chemotherapy
8
year surgery
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!