May a Single Presurgical High-Field MRI Sequence Replace Standard Radiographs for TPLO Surgical Planning in Dogs?

Vet Radiol Ultrasound

Ospedale Veterinario "I Portoni Rossi", Anicura Italy, Diagnostic Imaging Department (Mattei, Specchi), Surgical Department (Pratesi), Neuroradiology Department (Bernardini), Bologna, Italy.

Published: January 2025

Cranial cruciate ligament (CCL) disease causes variable stifle instability assessed by specific clinical tests. Radiographs are performed to measure the tibial plateau angle (TPA) for planning tibial plateau leveling osteotomy (TPLO) surgery. Concomitant damage to other intra-articular structures, for which clinical detection is unreliable, may occur and potentially affect the surgical outcome. Joint assessment during TPLO through instrumented inspection is therefore advised, though it increases the risk of complications. Magnetic resonance imaging offers a noninvasive alternative, adds information about intra- and periarticular structures, and could potentially be used for TPA measurements. This prospective study aimed to (1) assess the correlation between the TPA measured with the standard presurgical radiographs and with a single sagittal intermediate-weighted fat-saturated MRI sequence and (2) compare the surgical findings with the information obtained by the MRI sequence. Twenty-one stifles were included; TPA correlation using radiographs-MRI was available for 17 stifles, and surgery-MRI comparison was available for 18 stifles. A strong significant correlation was identified between the TPA measurements on radiographs-MRI (Pearson correlation coefficient 0.923; p-value <.0001). The sensitivity and specificity of MRI to detect surgically confirmed complete versus partial CCL rupture were 85.7% and 75%, respectively; MRI identified 7 of 8 surgically confirmed injured menisci and detected abnormal signal intensity in 8 of 10 medial menisci and nine caudal cruciate ligaments reported as normal intra-operatively. The MRI additionally identified abnormal subchondral bone signals in nine stifles and muscular hyperintensity in six cases. This presurgical MRI sequence might replace standard radiographs for TPA measurements and can provide information about concomitant joint injuries with potential prognostic impact.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vru.70005DOI Listing

Publication Analysis

Top Keywords

mri sequence
12
tibial plateau
8
tpa measurements
8
tpa
5
single presurgical
4
presurgical high-field
4
high-field mri
4
sequence replace
4
replace standard
4
standard radiographs
4

Similar Publications

Purpose: Isocitrate dehydrogenase (IDH) mutation status serves as a crucial prognostic indicator for glioma, typically assessed via immunohistochemical analysis post-surgery. Given the invasiveness of this approach, perhaps we can utilise convenient and noninvasive magnetic resonance imaging (MRI) methods to predict IDH mutation status. However, the current landscape lacks a standardised MRI technique for accurately predicting IDH mutations.

View Article and Find Full Text PDF

Background: Early detection of changes in lumbar intervertebral disc degeneration (IVDD) has great clinical significance. T1rho and UTE-T2* relaxometry are capable of providing information about biochemical changes in IVDD. However, they have not been previously analyzed and compared directly in the same patients.

View Article and Find Full Text PDF

Background: Pompe disease is a rare genetic disorder caused by a deficiency of the enzyme acid alpha-glucosidase. This condition leads to muscle weakness, respiratory problems, and heart abnormalities in affected individuals.

Methods: The aim of the study is to share our experience through cross sectional study of patients with infantile-onset Pompe disease (IOPD) with different genetic variations, resulting in diverse clinical presentations.

View Article and Find Full Text PDF

Background: Spinocerebellar ataxia type 3 (SCA3) is a hereditary disease caused by abnormally expanded CAG repeats in the ATXN3 gene. The study aimed to identify potential biomarkers for assessing therapeutic efficacy by investigating the associations between expanded CAG repeat size, brain and spinal cord volume loss, and motor functions in patients with SCA3.

Methods: In this prospective, cross-observational study, we analyzed 3D T1-weighted MRIs from 92 patients with SCA3 and 42 healthy controls using voxel-based morphometry and region of interest approaches.

View Article and Find Full Text PDF

Homozygous missense variant in causes early-onset neurodegeneration, leukoencephalopathy and autoinflammation.

J Med Genet

January 2025

Division of Clinical and Metabolic Genetics, Department of Paediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada

Biallelic pathogenic variants in cause a fatal autosomal recessive multisystem disorder characterized by recurrent autoinflammation, hypomyelination, progressive neurodegeneration, microcephaly, failure to thrive, liver dysfunction, respiratory chain defects and accumulation of glycogen in skeletal muscle. No missense variants in have been reported to date.We report a 6-year-old boy with microcephaly, global developmental delays, lower limb spasticity with hyperreflexia, epilepsy, abnormal brain MRI, failure to thrive, recurrent fevers and transaminitis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!