Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Paracetamol (PCM) is a commonly used analgesic and antipyretic agent for humans worldwide. However, PCM overdoses or overuse can cause health issues, such as hepatoxicity. As PCM is also used for the treatment of farm animals, it is essential to monitor these residues in animal-derived matrices at risk-based sites in order to minimize the intake of PCM through the food chain. In the present study, we have developed a novel carbon nanoparticle (CNP)-based indirect competitive lateral flow immunoassay (icLFIA) for the rapid detection of PCM in bovine urine. The developed icLFIA can detect PCM residues within 10 min, and its performance was validated according to Commission Implementing Regulation (EU) 2021/808, i.e., determination of the detection capability (CCβ), specificity, robustness, and stability. The CCβ of the icLFIA for PCM in bovine urine is 5 mg/L and the icLFIA is proven to be selective and specific towards PCM in bovine urine, as no matrix interference and cross-reactivity were observed, except for high concentrations of orthocetamol. The icLFIA for PCM in bovine urine is robust to (small) variations in reading time, but it remains necessary to strictly use a dilution ratio of running buffer/bovine urine of 80/20. Moreover, the produced icLFIAs are stable for at least 56 days under the stored conditions. In conclusion, the developed and validated icLFIA provides a rapid and cost-effective method for on-site monitoring of PCM abuse in cattle.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-024-05721-y | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!