Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The need to quantify brain glutathione (GSH) accurately by J-difference spectroscopy has stimulated assessment of the TE effects on GSH edited signals at the popular field strength 3 T. We performed multiple-TE J-difference MRS at two sites to evaluate the GSH T relaxation and TE dependence of the GSH signal resolution. Two 10-ms spectrally selective Gaussian editing RF pulses were implemented in 3 T MEGA-PRESS sequences at two sites having different vendors. The sequences were optimized, with numerical and phantom analyses, for editing of the GSH 2.95 ppm resonance. The timings of the editing pulses within the sequences were tailored for high-amplitude GSH signal production for a TE range of 58-160 ms. In vivo human brain data were collected at five TEs (58, 70, 88, 116, and 150 ms) from five subjects at each site. Following LCModel analysis of difference and edit-off spectra independently between the sites, metabolite T values were estimated with mono-exponential regression of the signal estimates. Simulations and phantom data indicated that the MEGA-edited GSH peak amplitude was progressively larger with increasing TE up to 125-140 ms and the maximum amplitude was 2- to 2.5-fold greater than the amplitude at TE of 58 ms. For in vivo data, the edited GSH peak was the largest at TE of 88 ms among the five TEs. Brain GSH T was measured as 88 ± 11 ms from 10 subjects, with no significant difference between the sites. The LCModel-returned correlation coefficient between GSH and co-edited N-acetylaspartate (NAA) multiplet was significantly smaller at short TEs than at long TEs. Our data suggest that MEGA-edited GSH signal undergoes extensive attenuation with increasing TE due to the fast T relaxation, and the edited GSH signal can be well resolved at short TEs with small interferences from adjacent co-edited NAA multiplet.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nbm.5313 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!