A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous measurement of liquid level and R.I. sensor using POF based on twisted structure. | LitMetric

In this paper, a dual-parameter liquid level and refractive index (R.I.) sensor is fabricated using three pieces of bare polymer optical fibers (POFs), which can independently and simultaneously sense the liquid level and R.I. The proposed sensor design utilizes the twisted coupling technique, in which two optical fibers are twisted and coupled with macro-bending. The liquid level measurement depends on the coupling loss, where the light is transmitted to emission fiber (EF) and twisted with coupled acceptor fiber (AF). The proposed liquid level sensor can measure depths up to 125 mm with a sensitivity of 8.03 nW/mm. Moreover, R.I. sensing depends on the twisted coupled macro-bending (TCMB) technique, where the EF generates bend loss and the AF couples the loss, where the coupled power varies due to the transformation in R.I. of coupling medium. The R.I. sensor revealing a notable sensitivity of -2663%/RIU and an impressive resolution of 3.754 × 10 in the different NaCl-saturated liquids featuring R.I. range extending from 1.333 to 1.361. The experimental findings indicate the sensor exhibits excellent stability and reliability. The sensor's straightforward, comprehensive, and cost-effective design enables its application in chemical, petroleum, and other industries.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41598-024-84964-2DOI Listing

Publication Analysis

Top Keywords

liquid level
20
twisted coupled
12
level sensor
8
optical fibers
8
coupled macro-bending
8
sensor
6
liquid
5
level
5
twisted
5
simultaneous measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!