In patients with obstructive jaundice, biliary decompression can be achieved by an endoprosthesis inserted by a percutaneous transhepatic approach. The prosthesis sometimes becomes dislodged and thus additional percutaneous transhepatic procedures may be required. To avoid this problem, a nondislodgeable endoprosthesis has been developed. The prosthesis is constructed with a layer of biocompatible material (hydrogel) on its surface. The hydrogel is located in grooves around the endoprosthesis and has the ability to absorb liquid, which increases its size. By placing the rings of hydrogel on either side of the obstruction, dislodgement of the prosthesis can be prevented. The nondislodgeable endoprosthesis has been inserted into 11 patients with biliary obstructions due to malignant strictures. No dislodgement has occurred and the established internal drainage reduced serum bilirubin levels without any major complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1250673 | PMC |
http://dx.doi.org/10.1097/00000658-198503000-00012 | DOI Listing |
Cochrane Database Syst Rev
January 2025
Department of Pharmacy Practice, University of Connecticut, Storrs, CT 06269, USA.
Background: Guideline-recommended strategies to interrupt chronic anticoagulation with warfarin or direct oral anticoagulants (DOAC) during the perioperative period of cardiac implantable electronic device (CIED) surgery differ worldwide. There is uncertainty concerning the benefits and harms of interrupted and uninterrupted anticoagulation in patients undergoing CIED surgery.
Objectives: To assess the benefits and harms of interrupted anticoagulation (IAC) with either warfarin or DOAC in the perioperative period of CIED surgery versus uninterrupted anticoagulation (UAC), with or without heparin bridging, during an equivalent time frame, for CIED surgery.
J Contemp Dent Pract
October 2024
Department of Prosthodontics, Dr. D.Y. Patil Dental College & Hospital, Dr. D.Y. Patil Vidyapeeth, Pune, Maharashtra, India.
Aim: The current study aimed to assess the oropharyngeal space using cone-beam computed tomography (CBCT) and its effect on airway volume both before and after denture placement.
Materials And Methods: For this investigation, a total of 15 individuals with fully edentulous upper and lower ridges, ranging in age from 40 to 70, were taken into consideration. A recording of the pulmonary function test was made both prior to and following full denture recovery.
Oper Orthop Traumatol
January 2025
Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.
Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.
Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.
Acta Bioeng Biomech
September 2024
Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.
: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.
View Article and Find Full Text PDFClin Oral Implants Res
January 2025
Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one-piece zirconia implants fabricated from 3Y-TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three-unit fixed dental prostheses (FDP) after five years in function.
Materials And Methods: Twenty-seven patients received a total of 54 implants in a one-stage surgery with immediate provisionalization.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!