A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A modified orthogonal-distance ray-tracer method applied to dual rotation PET systems. | LitMetric

A new projector, Orthogonal-Distance Ray-tracer Varying-Full Width at Half Maximum (OD-RT-VF), was developed to model a shift-variant elliptical point-spread function (PSF) response to improve the image quality of a preclinical dual-rotation PET system. Approach: The OD-RT-VF projector models different FWHM values of the PSF in multiple directions, using half-height and half-width tube-of-response (ToR) values. The OD-RT-VF method's performance was evaluated against the original OD-RT method and a ToR model with constant response. The evaluation involved simulations of NEMA NU 4-2008 image quality (IQ) and Derenzo phantoms, as well as a real mouse injected with [F]-NaF scanned with the easyPET.3D system. Main results:The OD-RT-VF method demonstrated superior image resolution and uniformity (11.9% vs 15.9%) compared to the OD-RT model. In micro-derenzo phantom simulations, it resolved rods down to 1.0 mm, outperforming the other methods. For IQ phantom simulations, the OD-RT-VF projector at convergency achieved hot rods recovery coefficients ranging from 22.5% to 93.3% and lower spillover ratios in cold regions of 0.22 and 0.33 for air and water, respectively. For bone radiotracer imaging, OD-RT-VF produced clearer images of major skeletal parts, with less noise compared to OD-RT and better resolution compared to ToR projectors. Significance: The study shows that the OD-RT-VF projector method enhances PET imaging by providing better resolution, uniformity, and image quality. This model, in addition to a list-mode and GPU-based reconstruction addressing the data sparsity of dual-rotation PET geometries, unlocks their imaging potential for small animal imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ada718DOI Listing

Publication Analysis

Top Keywords

image quality
12
od-rt-vf projector
12
orthogonal-distance ray-tracer
8
dual-rotation pet
8
resolution uniformity
8
compared od-rt
8
phantom simulations
8
better resolution
8
od-rt-vf
7
modified orthogonal-distance
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!