A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Real-time lung extraction from synthesized x-rays improves pulmonary image-guided radiotherapy. | LitMetric

Real-time lung extraction from synthesized x-rays improves pulmonary image-guided radiotherapy.

Phys Med Biol

Radiation Oncology, University of California San Francisco, 1600 Divisadero St, San Francisco, California, 94143, UNITED STATES.

Published: January 2025

Lung tumors can be obscured in X-rays, preventing accurate and robust localization. To improve lung conspicuity for image-guided procedures, we isolate the lungs in the anterior-posterior (AP) X-rays using a lung extraction network (LeX-net) that virtually removes overlapping thoracic structures, including ribs, diaphragm, liver, heart, and trachea. Approach: 73,965 thoracic 3DCTs and 106 thoracic 4DCTs were included. The 3D lung volume was extracted using an open-source lung volume segmentation model. AP digitally reconstructed radiographs (DRRs) of the full anatomy CT and extracted lungs were computed as the input and reference to train a network (LeX-net) to generate lung-extracted DRRs (LeX-net DRRs) from full anatomy DRRs, which adopted a Swin-UNet model with conditional GAN. Subsequently, the trained LeX-net on 3DCT was applied to 4DCT-derived DRRs. Lung tumor tracking was then performed on DRRs using a template-matching method on a holdoff 4DCT test set of 79 patients whose gross tumor volumes were smaller than 20 cm3. Main results: LeX-net successfully isolated the lungs in DRRs, achieving an SSIM of 0.9581 ± 0.0151 and a PSNR of 30.78 ± 2.50 on the testing set of 3DCT-derived DRRs. Its performance declined slightly when applied to the 4DCT but maintained useable lung-only 2D views. On the challenging test set including cases of organ overlap, high tumor mobility, and small tumor size, the individual tumor tracking error for LeX-net DRRs was 0.97 ± 0.86 mm, significantly lower than that of 3.13 ± 5.82 mm using the full anatomy DRRs. LeX-net improved success rates of using 5 mm, 3 mm, and 1 mm tracking windows from 88.1%, 80.0%, and 58.7% to 98.1%, 94.2%, and 73.8%, respectively. Significance: LeX-net removes overlapping anatomies and enhances visualization of the lungs in X-rays. The model trained using 3DCTs is generalizable to 4DCT-derived DRRs, achieving significantly improved tumor tracking outcome. .

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ada719DOI Listing

Publication Analysis

Top Keywords

full anatomy
12
tumor tracking
12
drrs
11
lung extraction
8
network lex-net
8
removes overlapping
8
lung volume
8
drrs full
8
drrs lex-net
8
lex-net drrs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!